Tuning
9.2 Tuning mode
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
315
9.2
Tuning mode
Responsivity of a machine can be optimized by tuning. The responsivity is reflected by
dynamic factor and determined by the servo gains that is set in the servo drive.
The servo gains are set by using a combination of parameters. These parameters influence
each other so you must consider the balance between set values when setting these values.
Generally, the responsivity of a machine with high rigidity can be improved by increasing the
servo gains; however, if the servo gains of a machine with low rigidity are increased, the
machine can vibrate and the responsivity cannot be improved.
NOTICE
Effectiveness of servo gains
The tuning function only uses the first group of servo gains (position loop gain 1, speed
loop gain 1 and speed loop integral time 1).
The following tuning functions are available for the SINAMICS V90 servo drive.
Select a tuning mode by setting the parameter p29021.
Parameter
Range
Default
Unit
Description
p29021
0 to 5
0
-
•
0: Auto tuning is disabled (manual tuning)
without changing servo gains relevant pa-
rameters.
•
1: One-button auto tuning. Identify the
ratio of load moment of inertia and auto-
matically adjust servo gains accordingly.
•
3: Real-time auto tuning. Identify the ratio
of load moment of inertia and automati-
cally adjust servo gains in real time.
•
5: Auto tuning is disabled (manual tun-
ing). All servo gains relevant parameters
are set to tuning default values.
Auto-tuning modes
The SINAMICS V90 supplies two auto-tuning modes: one-button auto tuning and real-time
auto tuning. The auto tuning function can optimize control parameters with ratio of machine
load moment of inertia (p29022) and set suitable current filter parameters to suppress the
machine resonance automatically. You can change the dynamic performance of the system
by setting different dynamic factors.
●
One-button auto tuning
–
One-button auto tuning estimates the machine load moment of inertia and mechanical
characteristics with internal motion commands. To achieve the desired performance,
you can execute the process many times before you control the drive with the host
controller. The maximum speed is limited by the rated speed.
Содержание SIMOTICS S-1FL6
Страница 1: ...SINAMICS V90 SIMOTICS S 1FL6 ...
Страница 2: ......
Страница 87: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 85 ...