Connecting
4.3 Control/status interface - X8
SINAMICS V90, SIMOTICS S-1FL6
132
Operating Instructions, 04/2019, A5E36037884-007
4.3.2
Pulse train inputs/encoder outputs (PTIs/PTOs)
4.3.2.1
PTIs
Two channels of pulse train input are available for the SINAMICS V90 servo drive:
●
24 V single end pulse train input
●
High-speed 5 V differential pulse train input (RS485)
When using the 24 V single end PTI:
When using the 5 V differential PTI:
Note
Only one channel can be used. The 24 V single end PTI is the factory setting of the
SINAMICS V90 servo drives.
When you choose to use the high-speed 5 V differential PTI (RS485), you must change the
value of parameter p29014 from 1 to 0. Refer to "Selecting a setpoint pulse train input
channel (Page 222)".