Connecting
4.2 Main circuit wiring
SINAMICS V90, SIMOTICS S-1FL6
118
Operating Instructions, 04/2019, A5E36037884-007
●
FSC and FSD
400 V variant
●
For FSAA and FSA
You can attach the motor power cable with the same method for 200 V variant drives of
frame sizes FSC and FSD.
●
For FSB and FSC
The FSB and FSC servo drives are equipped with barrier terminals for motor power
connection. You can fix the motor power cable on the servo drives by using the M4
screws with a tightening torque of 2.25 Nm (19.91 lbf.in).