Control functions
7.7 Torque control (T)
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
263
7.7.1.2
Torque control with fixed torque setpoint
Parameter settings
Parameter
Range
Default
Unit
Description
p29043
-100 to 100
0
%
Fixed torque setpoint
7.7.2
Direction and stop
Two digital input signals are used to control motor direction and run/stop:
●
CWE: clockwise enable
●
CCWE: counter-clockwise enable
The following table shows you in details:
Signal
Fixed torque setpoint
Analog torque setpoint
CCWE
CWE
+ polarity
- polarity
0 V
0
0
0
0
0
0
0
1
CW
CW
CCW
0
1
0
CCW
CCW
CW
0
1
1
0
0
0
0
Note
In S mode or T mode, when the servo motor is ready to run, signal CWE or CCWE is a must
to start running the motor.
For more information about the signals CWE and CCWE, refer to "DIs (Page 123)".
7.7.3
Speed limit
Refer to "Speed limit (Page 229)" for details.