Tuning
9.3 One-button auto tuning
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
319
Dynamic factor (p29020)
Machine rigidity
19
↓
...
35
High
If the dynamic factor setting cannot be increased up to the desired level because of machine
resonance beyond 250 Hz, the function of resonance suppression can be used to suppress
machine resonance and thus increase dynamic factor. Refer to Section "Resonance
suppression (Page 326)" for detailed information about the function of resonance
suppression.
Note
The tuning configuration parameters must be set carefully when the auto tuning function is
disabled (p29021=0).
After servo on, the motor will run with the test signal.
When the one-button auto tuning process completes successfully, parameter p29021 will be
set to 0 automatically. You can also set the parameter p29021 to 0 before servo on to
interrupt the one-button tuning process. Before you save the parameters on the drive, make
sure that p29021 has changed to 0.
When the one-button auto tuning process completes successfully, bit 0 of parameter p29300
will be set to 0 automatically or remain unchanged (= 0), which means the drive is in "S OFF"
state.
Note
Do not use the JOG function when you use the one-button tuning function.
Note
After the one-button tuning is activated, no operation will be allowed except the servo off and
quick stop with the digital input EMGS.
With one-button auto tuning, the servo drive can automatically estimate the ratio of load
moment of inertia and set the following relevant parameters accordingly.
Parameter
Range
Default
Unit
Description
p1414
0 to 3
0
-
Speed setpoint filter activation
p1415
0 to 2
0
-
Speed setpoint filter 1 type
p1417
0.5 to 16000
1999
Hz
Speed setpoint filter 1 denominator natural
frequency
p1418
0.001 to 10
0.7
-
Speed setpoint filter 1 denominator damping
p1419
0.5 to 16000
1999
Hz
Speed setpoint filter 1 numerator natural
frequency
p1420
0.001 to 10
0.7
-
Speed setpoint filter 1 numerator damping
p1441
0 to 50
0
ms
Actual speed smoothing time
p1656
0 to 15
1
-
Activates current setpoint filter
p1658
0.5 to 16000
1999
Hz
Current setpoint filter 1 denominator natural
frequency
p1659
0.001 to 10
0.7
-
Current setpoint filter 1 denominator damping
Содержание SIMOTICS S-1FL6
Страница 1: ...SINAMICS V90 SIMOTICS S 1FL6 ...
Страница 2: ......
Страница 87: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 85 ...
Страница 89: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 87 ...
Страница 342: ...Tuning 9 9 PI P switching SINAMICS V90 SIMOTICS S 1FL6 340 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 384: ...Parameters 10 2 Parameter list SINAMICS V90 SIMOTICS S 1FL6 382 Operating Instructions 04 2019 A5E36037884 007 ...