Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
345
Par. No.
Name
Min
Max
Factory
Setting
Unit Data
type
Effective
Can be
changed
p1120
Ramp-function generator
ramp-up time
0.000
999999.000 1
s
Float
IM
T, U
Description: The ramp-function generator ramps-up the speed setpoint from standstill (setpoint = 0) up to the
maximum speed (p1082) in this time.
Dependency: Refer to p1082
p1121
Ramp-function generator
ramp-down time
0.000
999999.000 1
s
Float
IM
T, U
Description: Sets the ramp-down time for the ramp-function generator.
The ramp-function generator ramps-down the speed setpoint from the maximum speed (p1082) down to
standstill (setpoint = 0) in this time.
Further, the ramp-down time is always effective for OFF1.
Dependency: Refer to p1082
p1130
Ramp-function generator
initial rounding-off time
0.000
30.000
0.000
s
Float
IM
T, U
Description: Sets the initial rounding-off time for the extended ramp generator. The value applies to ramp-up
and ramp-down.
Note: Rounding-off times avoid an abrupt response and prevent damage to the mechanical system.
p1131
Ramp-function generator
final rounding-off time
0.000
30.000
0.000
s
Float
IM
T, U
Description: Sets the final rounding-off time for the extended ramp generator. The value applies to ramp-up
and ramp-down.
Note: Rounding-off times avoid an abrupt response and prevent damage to the mechanical system.
p1215 *
Motor holding brake con-
figuration
0
3
0
-
I16
IM
T
Description: Sets the holding brake configuration.
Dependency: Refer to p1216, p1217, p1226, p1227, p1228
Caution: For the setting p1215 = 0, if a brake is used, it remains closed. If the motor moves, this will destroy
the brake.
Notice: If p1215 was set to 1 or if p1215 was set to 3, then when the pulses are suppressed, the brake is
closed even if the motor is still rotating.
Note: If a holding brake integrated in the motor is used, then it is not permissible that p1215 is set to 3.
The parameter can only be set to zero when the pulses are inhibited.
p1216 *
Motor holding brake
opening time
0
10000
100
ms Float
IM
T, U
Description: Sets the time to open the motor holding brake.
After controlling the holding brake (opens), the speed/velocity setpoint remains at zero for this time. After this,
the speed/velocity setpoint is enabled.
Dependency: Refer to p1215, p1217
Note: For a motor with integrated brake, this time is pre-assigned the value saved in the motor.
For p1216 = 0 ms, the monitoring and the message A7931 "Brake does not open" are deactivated.
Содержание SIMOTICS S-1FL6
Страница 1: ...SINAMICS V90 SIMOTICS S 1FL6 ...
Страница 2: ......
Страница 87: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 85 ...
Страница 89: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 87 ...
Страница 342: ...Tuning 9 9 PI P switching SINAMICS V90 SIMOTICS S 1FL6 340 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 384: ...Parameters 10 2 Parameter list SINAMICS V90 SIMOTICS S 1FL6 382 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 432: ......