Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
351
Par. No.
Name
Min
Max
Factory
Setting
Unit Data
type
Effective
Can be
changed
p1675
Current setpoint filter 4
numerator natural fre-
quency
0.5
16000.0
1000.0 Hz Float
IM
T, U
Description: Sets the numerator natural frequency for current setpoint filter 4 (general filter).
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1676
Current setpoint filter 4
numerator damping
0.000
10.000
0.010
-
Float
IM
T, U
Description: Sets the numerator damping for current setpoint filter 4.
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p2153
Speed actual value filter
time constant
0
1000000
0
ms Float
IM
T, U
Description: Sets the time constant of the PT1 element to smooth the speed/velocity actual value.
The smoothed actual speed/velocity is compared with the threshold values and is only used for messages and
signals.
p2161 *
Speed threshold 3
0.00
210000.00 10.00
rpm Float
IM
T, U
Description: Sets the speed threshold value for the signal that indicates the axis is stationary.
p2162 *
Hysteresis speed n_act >
n_max
0.00
60000.00
0.00
rpm Float
IM
T, U
Description: Sets the hysteresis speed (bandwidth) for the signal "n_act > n_max".
Note:
For a negative speed limit, the hysteresis is effective below the limit value and for a positive speed limit above
the limit value.
If significant overshoot occurs in the maximum speed range (for example, due to load shedding), you are
advised to increase the dynamic response of the speed controller (if possible). If this is insufficient, the hyste-
resis p2162 can be increased, but its value must not be greater than the value calculated by the formula be-
low when the motor maximum speed is sufficiently greater than the maximum speed p1082.
p2162 ≤ 1.05 × motor maximum speed
- maximum speed (p1082)
The range of the parameter is different when connect with different motors.
p2175 *
Motor blocked speed
threshold
0.00
210000.00 210000.
00
rpm Float
IM
T, U
Description: Sets the speed threshold for the message "Motor blocked".
Dependency: Refer to p2177.
p2177 *
Motor blocked delay time 0.000
65.000
0.500
s
Float
IM
T, U
Description: Sets the delay time for the message "Motor blocked".
Dependency: Refer to p2175.
p2525
LR encoder adjustment
offset
0
429496729
5
0
LU U32
IM
T
Description: For the absolute encoder adjustment, a drive determines the position offset.
Note: The position offset is only relevant for absolute encoders. The drive determines it when making the
adjustment and the user should not change it.
p2533
LR position setpoint filter
time constant
0.00
1000.00
0.00
ms Float
IM
T, U
Description: Sets the time constant for the position setpoint filter (PT1).
Содержание SIMOTICS S-1FL6
Страница 1: ...SINAMICS V90 SIMOTICS S 1FL6 ...
Страница 2: ......
Страница 87: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 85 ...
Страница 89: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 87 ...
Страница 342: ...Tuning 9 9 PI P switching SINAMICS V90 SIMOTICS S 1FL6 340 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 384: ...Parameters 10 2 Parameter list SINAMICS V90 SIMOTICS S 1FL6 382 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 432: ......