Commissioning
5.2 Initial commissioning in JOG mode
SINAMICS V90, SIMOTICS S-1FL6
176
Operating Instructions, 04/2019, A5E36037884-007
NOTICE
Device damage caused by inappropriate parameter settings for the motor
The inappropriate parameter settings for the motor may cause drive or motor damages.
•
Make sure that you have set the parameters for the motor appropriately.
Note
Plugging or unplugging the micro SD card/SD card will cause startup failure.
Do not plug or unplug the micro SD card/SD card during startup; otherwise, the drive will fail
to start up.
Note
In S control mode, if the motor shaft is blocked, the blocked torque is the current effective
torque. Long time shaft blocking can cause damage to the motor.
Engineering tool - SINAMICS V-ASSISTANT
You can use the engineering tool SINAMICS V-ASSISTANT to perform the trial operation.
SINAMICS V-ASSISTANT is a software tool that can be installed on a PC and runs on the
Windows operating system. It communicates with the SINAMICS V90 servo drive with a USB
cable (To ensure the stability of online commissioning, Siemens recommends you to use a
shielded USB cable of no longer than 3 m with ferrite cores on both ends.). With SINAMICS
V-ASSISTANT, you can change drive parameters and monitor drive working states in online
mode.
For more information, refer to the SINAMICS V-ASSISTANT Online Help. You can search
and download SINAMICS V-ASSISTANT from Technical support website
(
https://support.industry.siemens.com/cs/ww/en/
).
5.2
Initial commissioning in JOG mode
Commissioning purpose
When the servo drive is powered on for the first time, you can perform a test run with the
BOP or the engineering tool SINAMICS V-ASSISTANT to check:
●
Whether the line supply has been connected correctly
●
Whether the 24 VDC power supply has been connected correctly
●
Whether the cables (power cable, encoder cable, and brake cable) between the servo
drive and the servo motor have been connected correctly
●
Whether the motor speed and direction of rotation are correct.
Содержание SIMOTICS S-1FL6
Страница 1: ...SINAMICS V90 SIMOTICS S 1FL6 ...
Страница 2: ......
Страница 87: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 85 ...
Страница 89: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 87 ...
Страница 342: ...Tuning 9 9 PI P switching SINAMICS V90 SIMOTICS S 1FL6 340 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 384: ...Parameters 10 2 Parameter list SINAMICS V90 SIMOTICS S 1FL6 382 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 432: ......