Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
364
Operating Instructions, 04/2019, A5E36037884-007
Par. No.
Name
Min
Max
Factory
Setting
Unit Data
type
Effective
Can be
changed
p29070[0..
.2] *
Speed limit positive
0
210000
210000 rpm Float
IM
T
Description: Positive speed limit.
Three internal speed limits in total are available.
You can select the internal parameters or the analog input as the source of the speed limit with the combina-
tion of the digital input signals SLIM1 and SLIM2.
p29071[0..
.2] *
Speed limit negative
-210000
0
-
210000
rpm Float
IM
T
Description: Negative speed limit.
Three internal speed limits in total are available.
You can select the internal parameters or the analog input as the source of the speed limit with the combina-
tion of the digital input signals SLIM1 and SLIM2.
p29075
Speed clamp threshold
0
200
200
rpm Float
IM
T
Description: The threshold for the zero speed clamp.
If the function of zero speed clamp has been enabled under the speed control mode, the motor speed is
clamped to 0 when both the setpoint speed and the actual speed are below this threshold.
p29078
Speed reach threshold
0.0
100.0
10
rpm Float
IM
T
Description: Speed reached range (deviation between setpoint and motor speed)
p29080
Overload threshold for
output signal triggering
10
300
100
%
Float
IM
T
Description: Overload threshold for the output power.
p29090
Offset Adjustment for
Analog output 1
-0.50
0.50
0.00
V
Float
IM
T
Description: Offset adjustment for analog output 1.
p29091
Offset adjustment for
analog output 2
-0.50
0.50
0.00
V
Float
IM
T
Description: Offset adjustment for analog output 2.
p29110[0..
.1] **
Position loop gain
0.000
300.000
[0]
Motor
de-
pendent
[1]
1.000
100
0/mi
n
Float
IM
T, U
Description: Position loop gain.
Two position loop gains in total are available. You can switch between these two gains by configuring the
digital input signal G-CHANGE or setting relevant condition parameters.
The first position loop gain is the default setting.
Dependency: The parameter value will be set to default after configuring a new motor ID (p29000).
p29111
Speed pre-control factor
(feed forward)
0.00
200.00
0.00
%
Float
IM
T, U
Description: Setting to activate and weight the speed pre-control value.
Value = 0%: The pre-control is deactivated.
Содержание SIMOTICS S-1FL6
Страница 1: ...SINAMICS V90 SIMOTICS S 1FL6 ...
Страница 2: ......
Страница 87: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 85 ...
Страница 89: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 87 ...
Страница 342: ...Tuning 9 9 PI P switching SINAMICS V90 SIMOTICS S 1FL6 340 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 384: ...Parameters 10 2 Parameter list SINAMICS V90 SIMOTICS S 1FL6 382 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 432: ......