Parameters
10.2 Parameter list
SINAMICS V90, SIMOTICS S-1FL6
348
Operating Instructions, 04/2019, A5E36037884-007
Par. No.
Name
Min
Max
Factory
Setting
Unit Data
type
Effective
Can be
changed
p1418
Speed setpoint filter 1
denominator damping
0.001
10.000
0.700
-
Float
IM
T, U
Description: Sets the denominator damping for speed setpoint filter 1 (PT2, general filter).
Dependency: Refer to p1414, p1415
Note: This parameter is only effective if the speed filter is parameterized as a PT2 low pass or as general
filter.
p1419
Speed setpoint filter 1
numerator natural fre-
quency
0.5
16000.0
1999.0 Hz Float
IM
T, U
Description: Sets the numerator natural frequency for speed setpoint filter 1 (general filter).
Dependency: Refer to p1414, p1415
Note: This parameter is only effective if the speed filter is set as a general filter. The filter is only effective if the
natural frequency is less than half of the sampling frequency.
p1420
Speed setpoint filter 1
numerator damping
0.001
10.000
0.700
-
Float
IM
T, U
Description: Sets the numerator damping for speed setpoint filter 1 (general filter).
Dependency: Refer to p1414, p1415
Note: This parameter is only effective if the speed filter is set as a general filter.
p1421
Speed setpoint filter 2
type
0
2
0
-
I16
IM
T, U
Description: Sets the type for speed setpoint filter 2.
Dependency:
PT1 low pass: p1422
PT2 low pass: p1423, p1424
General filter: p1423 ... p1426
p1422
Speed setpoint filter 2
time constant
0.00
5000.00
0.00
ms Float
IM
T, U
Description: Sets the time constant for the speed setpoint filter 2 (PT1).
Dependency: Refer to p1414, p1421
Note: This parameter is only effective if the speed filter is set as a PT1 low pass.
p1423
Speed setpoint filter 2
denominator natural fre-
quency
0.5
16000.0
1999.0 Hz Float
IM
T, U
Description: Sets the denominator natural frequency for speed setpoint filter 2 (PT2, general filter).
Dependency: Refer to p1414, p1421
Note: This parameter is only effective if the speed filter is parameterized as a PT2 low pass or as general
filter.
The filter is only effective if the natural frequency is less than half of the sampling frequency.
p1424
Speed setpoint filter 2
denominator damping
0.001
10.000
0.700
-
Float
IM
T, U
Description: Sets the denominator damping for speed setpoint filter 2 (PT2, general filter).
Dependency: Refer to p1414, p1421
Note: This parameter is only effective if the speed filter is parameterized as a PT2 low pass or as general
filter.
Содержание SIMOTICS S-1FL6
Страница 1: ...SINAMICS V90 SIMOTICS S 1FL6 ...
Страница 2: ......
Страница 87: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 85 ...
Страница 89: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 87 ...
Страница 342: ...Tuning 9 9 PI P switching SINAMICS V90 SIMOTICS S 1FL6 340 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 384: ...Parameters 10 2 Parameter list SINAMICS V90 SIMOTICS S 1FL6 382 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 432: ......