SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 04/2019, A5E36037884-007
81
Mounting
3
3.1
Mounting the drive
Protection against the spread of fire
The device may be operated only in closed housings or in control cabinets with protective
covers that are closed, and when all of the protective devices are used. The installation of
the device in a metal control cabinet or the protection with another equivalent measure must
prevent the spread of fire and emissions outside the control cabinet.
Protection against condensation or electrically conductive contamination
Protect the device, e.g. by installing it in a control cabinet with degree of protection IP54
according to IEC 60529 or NEMA 12. Further measures may be necessary for particularly
critical operating conditions.
If condensation or conductive pollution can be excluded at the installation site, a lower
degree of control cabinet protection may be permitted.
WARNING
Death or severe personal injury from harsh installation environment
A harsh installation environment can jeopardize personal safety and equipment.
•
Do not install the drive and the motor in an area subject to inflammables or
combustibles, water or corrosion hazards.
•
Do not install the drive and the motor in an area where it is likely to be exposed to
constant vibrations or physical shocks.
•
Do not keep the drive exposed to strong electro-magnetic interference.
CAUTION
Risk of injury due to touching hot surfaces
There is a risk of injury if you touch the hot surfaces, because surfaces of the drive can
reach a high temperature during operation and for a short time after switching-off.
•
Avoid coming into direct contact with the drive surface.
For mounting conditions, see Technical data - servo drives (Page 61).
Содержание SIMOTICS S-1FL6
Страница 1: ...SINAMICS V90 SIMOTICS S 1FL6 ...
Страница 2: ......
Страница 87: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 85 ...
Страница 89: ...Mounting 3 1 Mounting the drive SINAMICS V90 SIMOTICS S 1FL6 Operating Instructions 04 2019 A5E36037884 007 87 ...
Страница 342: ...Tuning 9 9 PI P switching SINAMICS V90 SIMOTICS S 1FL6 340 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 384: ...Parameters 10 2 Parameter list SINAMICS V90 SIMOTICS S 1FL6 382 Operating Instructions 04 2019 A5E36037884 007 ...
Страница 432: ......