background image

 

MOTOR FOR SLIDING GATES 

 

SERIE GR6  –  220V

 

 

SAFETY 

 

Our compliments for your excellent choice. Your new 
electromechanical gear motor has been produced according to a 
high quality and a strict reliability, that's why it will assure you long-
lasting performances. 
This booklet will offer you all the pieces of information you may need 
to install your gear motor and to safeguard your safety. 

However, the caution is unquestionably indispensable and 
nothing is better than preventing accidents. 

All our products have been made in conformity with the regulations 
in force. 

WARNING:

 any repair or adjustment of the working machinery is 

strictly prohibited unless all the necessary precautions (electrical 
supply disconnected and motor off) have been taken in order to 
avoid possible accidents. 

WARNING:

 The feeder line has to be protected for the max. current 

in blocked rotor condition. 

WARNING: 

Install the motor on gate who are in conformity with the 

EN 12604 

WARNING:

 Execute the measurement of the force produced by the 

motor and take the measures expected by the EN 12445 

WARNING:

 any repair must be carried out by qualified people. 

All moving mechanisms must be provided with suitable protections. 

WARNING: 

Keep the automatic controls out of the reach of 

childrens. The controls must be installed at a minimum high of 1,5 
mt. from the ground surface and out of the work of mobile parts. 

WARNING: 

command pulses must be given from positions where 

the gate is visible. 

WARNING: 

use the transmitters only if you can see the gate. 

WARNING:

 GR Srl is not responsible for possible damages or 

injuries to people, objects or animals, caused by any unauthorised 
modification of the product. 
Keep scrupulously this booklet in a suitable place well known by all 
the interested people. 
In order to make the automation work efficiently; the gate to 
automate must have the following characteristics: 
- it must be balanced; 
- it must oscillate fluently; 
- you have to carry out the manual closing and opening the gate 
without any effort; 
- remember that the motorization has been planned in order to help 
you use the gate. This means that it does not resolve the problems 
caused by an inadequate installation or by a poor upkeep of the 
gate. 

 

SAFETY RULES 

  

During the installation and the use of the automation, you have to 
pay attention to the following safety rules: 
- Security distance! 
- Mechanism in movement! 
- Do not install the automation in places with presence of 
iniammable gasses! 
- Electric shock! 
- Use the gloves! 
- Use glasses for welding! 
- Keep the protection carter! 

 

EQUIPMENT 

  

In order to install the automation you have to provide yourself with 
keys, screwdriver, metre, slope detector (water level), saw, drilling 
machine and welding machine. 

 

 

 

TECHNICAL DATA 

 

 

DIMENSIONS 

 

 

 
A = 80 = DISTANCE BETWEEN THE FIXATION HOLE OF THE 
RACK AND THE SURFACE OF THE BASEMENT PLATE OF 
THE MOTOR. 
1 - GATE 
2 - BASEMENT PLATE 
B – POSITION OF BASEMENT PLATE WITH THE CORRECT 
ORIENTATION OF THE HOLE FOR THE CABLES 

 

CONFORMITY DECLARATION: 

 

It’s in accordance with Machine Directive 39/89/CE and following 
modify. 
It’s in accordance with the following directive CE: 
Electromagnetic compatibility Directive 89/336/CEE and 
following modify. 
Low tension Directive 73/23/CEE and following modify. 
Have been applied the following harmonized norms: 
EN292/1/2, EN 294, EN60335-1, UNI EN 12453, and what 
applicable of the EN12445-2000. 

 
 

GR6 220-230 Volt 

Power supply 

220-230 Vac 

Current absorbed 

1,5 Ampere 

Capacitor 

12,5 

µ

Farad

 

Power absorbed 

350 Watt 

RPM 1400 

rpm 

Thermal protection 

150° 

Torque 20,5 

Nm 

Max. thrust 

600 N 

Wotking temperature 

-25+75°C 

Lubrication Grease 
Motor weight 

6,3 – 7,5 Kg. 

Max. wing weight 

600 Kg. 

Speed 

10 m/ min. 

Protection level 

IP55 

Содержание GR6 Series

Страница 1: ... by all the interested people In order to make the automation work efficiently the gate to automate must have the following characteristics it must be balanced it must oscillate fluently you have to carry out the manual closing and opening the gate without any effort remember that the motorization has been planned in order to help you use the gate This means that it does not resolve the problems c...

Страница 2: ... the lever open until the end of installation FIXING OF THE RACK Put the first piece of the rack on top of the spur wheel And make it run until point 1 see Fig 1 Weld or screw the first pin of the rack to the gate Add all the other pieces of the rack in order they are perfectly aligned to the first FINAL OPERATION Take out from the bottom of the motor the 4 shims and fix the motor to the foundatio...

Страница 3: ...r safety if necessary integrating those in the manual for installation of the door gate and give the user a copy Compile the proof book and give the user a copy see facsimile in Annex 1 Draft the EC declaration of conformity see facsimile in Annex 2 and give the user a copy Fill in the label or plate with CE marking and attach it to the motorised door gate N B The technical file must be held and m...

Страница 4: ...ITH THE MACHINERY DIRECTIVE 98 37 EEC AND THE STANDARDS EN 13241 1 EN 12453 EN 12445 The risks listed below follow the sequence of the installation process These risks are those which are commonly present in motorised doors gates systems According to the various situations consideration therefore has to be made of any possible additional risks and exclude those which are not applicable The solutio...

Страница 5: ...e considered The graph indicates the maximum values of the dynamic static and residual operating forces in relation to the various positions of the leaf N B With reference to the measurement points with L 50 300 and 500 mm the maximum dynamic force value permitted is 400 N F If the values of the forces are higher install a protective device in accordance with the standard EN 12978 for example a se...

Страница 6: ...and the average value considered F If the values of the forces are higher install a protective device in accordance with the standard EN 12978 for example a sensitive edge and repeat the measurement 6 Shearing between the sliding leaf and fixed part during the movement of opening and closure Figure 1 risk C F The leaf of the sliding gate and the enclosure must be free from gaps or the gaps must be...

Страница 7: ... in accordance with current regulations and as indicated in the installation manual of the drive unit N B If the electrical supply line is already set up via both a socket and a connector block declarations of conformity to Italian law no 46 90 are not necessary F Use CE marked components pursuant to the EMC Directive 89 336 EEC Carry out the installation as indicated in the manual for installatio...

Страница 8: ...afety devices installed 1 7 1 1 7 2 1 7 3 1 7 4 1 6 1 1 1 2 Integration principles for safety and information 19 Signalling equipment 20 Warnings 21 Marking 22 Operating instructions 23 Maintenance 24 Unprotected residual risks F A flashing light should be installed in a visible position to indicate movement of the leaf F Traffic lights can be installed to control vehicle traffic F Reflectors can ...