Configuration / project engineering
5.3 Configuring the communication
ET 200pro FC
80
Operating Instructions, 07/2016, A5E01100763B AC
Points to note when using the PROFIdrive profile
The alarm mode of the ET 200pro slave must be set to DPV1.
●
Double-click the ET 200pro system
●
Select the "Operating parameters" tab
Image 5-20 Operating parameters
●
The diagnostic interrupt parameter of the frequency converter enables the S7 system
diagnostics in PROFIdrive mode.
–
No diagnostic messages: 0
–
Diagnostic messages: 1.
Note
Enabled diagnostic messages require troubleshooting in the OB82 of the user
program. (If there is no OB82 in the user program, the S7 enters the "STOP" state in
the event of an error.)