MX-C250 SIMULATION 6 – 12
21
21-1
Purpose
Setting
Function (Purpose)
Used to set the maintenance cycle.
Section
Operation/Procedure
* Do not change the default setting value of the maintenance
counter on SIM21-1. The replacement timing of the fusing
cleaning roller, the filter and PS paper dust removal cleaner may
not clarify.
1) Select a target item of setting with 10 keys.
2) Press [OK]/[START] key. (The set value is saved.)
22
22-1
Purpose
Adjustment/Setting/Operation data output/
Check
Function (Purpose)
Used to check the print count value in each
section and each operation mode.
(Used to check the maintenance timing.)
Section
Operation/Procedure
Change the display page with Arrow keys.
22-2
Purpose
Adjustment/Setting/Operation data check
Function (Purpose)
Used to check the total numbers of misfeed
and troubles. (When the number of total
jam is considerably great, it is judged as
necessary for repair.)
Section
Operation/Procedure
The paper jam, trouble counter value is displayed.
22-3
Purpose
Adjustment/Setting/Operation data check
Function (Purpose)
Used to check misfeed positions and the
misfeed count of each position.
* Presumption of the faulty point by this
data is possible.
Section
Operation/Procedure
The paper jam and misfeed history is displayed from the latest one
up to 50 items. (The old ones are deleted sequentially.)
22-4
Purpose
Adjustment/Setting/Operation data check
Function (Purpose)
Used to check the trouble (self diag) his-
tory.
Section
Operation/Procedure
The trouble history is displayed from the latest one up to 30 items.
(The old ones are deleted sequentially.)
* For the list of the trouble codes: Refer to "[6] SELF DIAG AND
TROUBLE CODE".
22-5
Purpose
Others
Function (Purpose)
Used to check the ROM version of each
unit (section).
Section
Firmware
Operation/Procedure
The ROM version of the installed unit in each section is displayed.
When there is any trouble in the software, use this simulation to
check the ROM version, and upgrade the version if necessary.
22-6
Purpose
Adjustment/Setting/Operation data check
Function (Purpose)
Used to output various adjustment/setting
data (simulations, FAX soft switch counter),
the firmware version, the counter list and
the process control data.
Section
Item/Display
Content
Setting range
Default
value
1
MAINTENANCE
COUNTER
(TOTAL)
Maintenance
counter
(Total)
0 : Default
1 - 300: 1K - 300K
999 : Free
75K
2
MAINTENANCE
COUNTER
(COLOR)
Maintenance
counter
(Color)
0 : Default
1 - 300: 1K - 300K
999 : Free
45K
Item
Display (Coun-
ter)
Content
NOTE
Total output
quantity
TOTAL OUT
(BW)
Total output quan-
tity of black and
white
All prints includ-
ing jams
TOTAL OUT
(COL)
Total output quan-
tity of color
All prints includ-
ing jams
Total use
quantity
TOTAL (BW)
Total use quantity
of black and white
Effective paper
(including self
print, excluding
jams)
TOTAL (COL)
Total use quantity
of full color
Effective paper
(including self
print, excluding
jams)
Copy
COPY (BW)
Black and white
copy counter
Billing target
(excluding self
print)
COPY (COL)
Full color copy
counter
Billing target
(excluding self
print)
PRINT (BW)
Black and white
print counter
Billing target
(excluding self
print)
PRINT (COL)
Full color print
counter
Billing target
(excluding self
print)
Other
OTHER (BW)
Black and white
other counter
Self print quantity
OTHER (COL)
Color other coun-
ter
Self print quantity
Display/Item
Content
MACHINE JAM
Machine JAM counter
(R)SPF JAM
(R)SPF JAM counter
TROUBLE
Trouble counter
S/N
Serial No.
MCU BOT
MCU (Boot section)
MCU PRG
MCU (Program section)
MCU PRP
MCU (Property)
PNL BOT
PNL (Boot section)
PNL PRG
PNL (Program section)
PNL COM
PNL (Common Data)
PNL CPY
PNL (Copy Data)
PNL FAX
PNL (FAX Data)