MX-C250 SIMULATION 6 – 55
51
51-1
Purpose
Adjustment/Setup
Function (Purpose)
Used to adjust the ON/OFF timing of the
secondary transport voltage.
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
When the adjustment value is decreased, the transfer ON/OFF tim-
ing for the paper is advanced. When the adjustment value is
increased, the timing is delayed.
When the adjustment value is changed by 1, the timing is changed
by about 10ms. The setting range is -490 - +490ms.
51-2
Purpose
Adjustment/Setup
Function (Purpose)
Used to adjust the contact pressure (deflec-
tion amount) on paper by the main unit and
the RSPF resist roller. (This adjustment is
performed when there is a considerable
variation in the print image position on the
paper or when paper jams frequently
occur.)
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
<Adjustment value>
When the adjustment value is increased, the warp amount is increased. When the adjustment value is decreased, the warp amount is
decreased.
When the adjustment value is changed by 1, the stop timing is changed by 0.1mm.
53
53-8
Purpose
Adjustment
Function (Purpose)
Used to adjust the document lead edge ref-
erence and the RSPF mode document
scan position.
Section
Operation/Procedure
Select an adjustment item [AUTO].
<AUTO: Document lead edge reference (RRCA) adjustment>
1) Enter the set value with 10 keys.
2) Press [OK]/[START] key.
The set value in step 2) is saved.
53-9
Purpose
Adjustment
Function (Purpose)
Used to detect the dirt of the SPF unit
Section
Operation/Procedure
1) Select an item to be set with Arrow keys..
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
Item/Display
Content
Defaul
t value
Default
value
1
TC2 ON
TIMING
Secondary transfer voltage
ON timing setting
1 - 99
40
2
TC2 OFF
TIMING
Secondary transfer voltage
OFF timing setting
1 - 99
60
Mode
Display/Item
Content
Setting
range
Default
value
1
TRAY1
Main unit cassette / deflection adjustment value (Plain paper)
LT size (215mm) or less
1 - 99
60
2
MANUAL PLAIN PAPER
Manual feed tray/deflection adjustment value (Plain paper)
LT size (215mm) or less
1 - 99
40
3
MANUAL HEAVY PAPER
Manual feed tray/deflection adjustment value (Heavy paper)
LT size (215mm) or less
1 - 99
60
4
MANUAL ENV
Manual feed tray/deflection adjustment value (Envelope)
-
1 - 99
60
5
ADU PLAIN PAPER
ADU/deflection adjustment value (Plain paper)
LT size (215mm) or less
1 - 99
50
6
DESK
DESK/deflection adjustment value (Plain paper)
LT size (215mm) or less
1 - 99
50
Item/Display
Content
Setting
range
Default
value
MANUAL
ADJUST VALUE
SPF reading position
adjustment (Manula adjust-
ment)
0-99
(0.1mm unit)
50
Item/Display
Contents
Range
Default
value
1
POS SET
START
RSPF front surface opti-
mum scan position detec-
tion setting (When starting)
0 - 1
0:OFF/
1:ON
0
2
POS SET
JOB
RSPF front surface opti-
mum scan position detec-
tion setting (After a job)
0 - 1
0:OFF/
1:ON
1
3
POS LV
RSPF front surface opti-
mum scan position detec-
tion level setting
0 - 1
0:Weak
1:Middle
2:Strong
1