MX-C250 SIMULATION 6 – 32
44-4
Purpose
Setting
Function (Purpose)
Used to set the conditions of the high den-
sity process control operation.
Section
Process
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
NOTE:
Set the items to the default values unless a change is spe-
cially required.
44-6
Purpose
Adjustment
Function (Purpose)
Used to execute the high density process
control forcibly.
Section
Process
Operation/Procedure
When [OK]/[START] key is pressed, the adjustment is exe-
cuted automatically.
After completion of the adjustment, the adjustment result is
displayed. (Refer to the table below.)
If the adjustment is not executed normally, "ERROR" is dis-
played.
REG_R_LED_ADJ
Registration sensor R adjustment abnor-
mality
REG_F_GRND
F registration basis material reading
abnormality
REG_R_GRND
R registration basis material reading
abnormality
Item/Display
Content
Setting
range
Default
value
1
PCS TARGET
Sensor target set value
1 - 255
204
2
PCS ADJ LIM
Sensor adjustment target limit
value
1 - 255
8
3
BELT G DIF
Effective difference between the
belt circuit substrate upper and
lower limit values
1 - 255
1
4
B_BK STD DIF
Bias (for black) Target calcula-
tion difference
0 - 255
0
5
B PAT INT
Patch bias output interval
1 - 255
60
6
Y TAR ID
Patch density standard value
(yellow)
1 - 255
45
7
M TAR ID
Patch density standard value
(magenta)
1 - 255
50
8
C TAR ID
Patch density standard value
(cyan)
1 - 255
50
9
K TAR ID
Patch density standard value
(black)
1 - 255
45
10
HV BK_GR LIM
Patch position substrate light
receiving effective range value
1 - 255
60
11
LED ADJ
ROUGH
LED radiation quantity adjust-
ment rough 1step
1 - 255
5
12
LED ADJ
ROUGH
UPPER
LED radiation quantity adjust-
ment rough 1step execution
threshold level upper
1 - 255
240
13
LED ADJ
ROUGH
LOWER
LED radiation quantity adjust-
ment rough 1step execution
threshold level lower
1 - 255
140
14
K_PAT TAR-
GET UPPER 1
Simplified process control solid-
patch transition judgment to high
density process control upper
limitation 1 (K-patch)
1 - 255
10
15
K_PAT TAR-
GET LOWER 1
Simplified process control solid-
patch transition judgment to high
density process control lower
limitation 1 (K-patch)
1 - 255
10
16
K_PAT TAR-
GET UPPER 2
Simplified process control solid-
patch transition judgment to high
density process control upper
limitation 2 (K-patch)
1 - 255
15
17
K_PAT TAR-
GET LOWER 2
Simplified process control solid-
patch transition judgment to high
density process control lower
limitation 2 (K-patch)
1 - 255
15
18
K_HT TARGET
UPPER 1
Simplified process control half-
tone-patch transition judgment
to high density process control
upper limitation 1 (K-patch)
1 - 255
10
19
K_HT TARGET
LOWER 1
Simplified process control half-
tone-patch transition judgment
to high density process control
lower limitation 1 (K-patch)
1 - 255
10
Error name
Error content
20
K_HT TARGET
UPPER 2
Simplified process control half-
tone-patch transition judgment
to high density process control
upper limitation 2 (K-patch)
1 - 255
15
21
K_HT TARGET
LOWER 2
Simplified process control half-
tone-patch transition judgment
to high density process control
lower limitation 2 (K-patch)
1 - 255
15
22
CL_PAT TAR-
GET UPPER 1
Simplified process control solid-
patch transition judgment to high
density process control upper
limitation 1 (CL-patch)
1 - 255
10
23
CL_PAT TAR-
GET LOWER 1
Simplified process control solid-
patch transition judgment to high
density process control lower
limitation 1 (CL-patch)
1 - 255
10
24
CL_PAT TAR-
GET UPPER 2
Simplified process control solid-
patch transition judgment to high
density process control upper
limitation 2 (CL-patch)
1 - 255
15
25
CL_PAT TAR-
GET LOWER 2
Simplified process control solid-
patch transition judgment to high
density process control lower
limitation 2 (CL-patch)
1 - 255
15
26
CL_HT TAR-
GET UPPER 1
Simplified process control half-
tone-patch transition judgment
to high density process control
upper limitation 1 (CL-patch)
1 - 255
10
27
CL_HT TAR-
GET LOWER 1
Simplified process control half-
tone-patch transition judgment
to high density process control
lower limitation 1 (CL-patch)
1 - 255
10
28
CL_HT TAR-
GET UPPER 2
Simplified process control half-
tone-patch transition judgment
to high density process control
upper limitation 2 (CL-patch)
1 - 255
15
29
CL_HT TAR-
GET LOWER 2
Simplified process control half-
tone-patch transition judgment
to high density process control
lower limitation 2 (CL-patch)
1 - 255
15
30
SP_PAT COEF
UPP DIF
Simplified process control den-
sity coefficient upper threshold
level
1 - 255
10
31
SP_PAT COEF
LOW DIF
Simplified process control den-
sity coefficient lower threshold
level
1 - 255
10
Result display
Content description
COMPLETE
Normal complete
ERROR
Abnormal end
INTERRUPTION
Forcible interruption
Details of error display
Content description
CL_SEN_ADJ_ERR
Color sensor adjustment abnormality
BK_SEN_ADJ_ERR
Black sensor adjustment abnormality
K_HV_ERR
K high density process control abnormality
C_HV_ERR
C high density process control abnormality
M_HV_ERR
M high density process control abnormality
Y_HV _ERR
Y high density process control abnormality
TIMEOUT_ERR
Time out
Item/Display
Content
Setting
range
Default
value