MX-C250 SIMULATION 6 – 46
When the adjustment values of SLOPE are changed, the gamma of
the total image is changed.
When the adjustment value of SLOPE is increased, the image con-
trast of the total image is increased. When the adjustment value is
decreased, the image contrast of the total image is decreased.
When the adjustment value of INTERCEPT is increased, the image
density of the total image is increased. When the adjustment value
is decreased, the image density of the total image is decreased.
46-32
Purpose
Adjustment/Setup
Function (Purpose)
Used to set the AE reactivity control.
Section
Operation/Procedure
1) Select an item to be set with 10 keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
46-37
Purpose
Adjustment/Setup
Function (Purpose)
Used to adjust the color document repro-
ducibility in the monochrome copy mode.
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
This simulation is used to adjust the reproducibility of red and yel-
low images when copy a color document of red and yellow images
in the gray push scanning mode.
When the adjustment values of items 1 and 2 are decreased, the
copy density of yellow images is increased. When the adjustment
values are increased, the density is decreased.
When the adjustment value of item 1 is decreased and the adjust-
ment value of item 2 is increased, the copy density of red images is
increased. When the adjustment value of item 1 is increased and
the adjustment value of item 2 is decreased, the copy density is
decreased.
46-39
Purpose
Adjustment/Setup
Function (Purpose)
Used to adjust the sharpness of FAX send
images.
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Determine the value and starts the test print with pressing
[START] key.
Input small numeric value to obtain crispy image. Input large
numeric value to decrease moire.
46-40
Purpose
Adjustment/Setup
Function (Purpose)
Used to adjust the FAX send image density.
(Collective adjustment of all the modes)
Section
Operation/Procedure
1) Set the original on the original table.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
When [START] key is pressed, the adjustment value is set and
the scanned document image is outputted.
46-41
Purpose
Adjustment/Setup
Function (Purpose)
Used to adjust the FAX send image density.
(Normal)
Section
Operation/Procedure
1) Set the original on the original table.
2) Select an item to be set with Arrow keys.
3) Press [OK]/[START] key
When [START] key is pressed, the adjustment value is set and
the scanned document image is outputted.
46-42
Purpose
Adjustment/Setup
Function (Purpose)
Used to adjust the FAX send image density.
(Fine)
Section
5
PHOTO
(SLOPE)
Character edge / pho-
tography mode gamma
skew adjustment
1
99
6
PHOTO (INTER-
CEPT)
1
99
Item/Display
Content
Set-
ting
range
Default
value
1
COLOR COPY
AE reactivity control
(COLOR COPY)
0 - 255
160
2
MONO COPY
AE reactivity control
(MONO COPY)
0 - 255
160
3
FAX
AE reactivity control
(FAX)
0 - 255
160
4
COLOR PUSH
AE reactivity control
(COLOR PUSH)
0 - 255
160
5
MONO PUSH
AE reactivity control
(MONO PUSH)
0 - 255
160
Item/Display
Content
Setting
range
Default
value
1
R-Ratio
Gray making setting (R)
0 - 999
347
2
G-Ratio
Gray making setting (G)
0 - 999
701
Item/Display
(Copy mode)
Content
MIn
Max
Item/Display
Content
Set-
ting
range
Default
value
1
STD
Normal
0 - 2
1
2
FINE
Fine
0 - 2
1
3
S-FINE
Super Fine
0 - 2
1
4
FINE/HT
Fine + Halftone
0 - 2
1
5
S-FINE/HT
Super Fine + halftone
0 - 2
1
Item/Display
Content
Set-
ting
range
Default
value
1
AUTO
Used to adjust the FAX
send image density. (Col-
lective adjustment of all the
modes)
1 - 99
50
Item/Display
Content
Setting
range
Default
value
1
AE
Auto exposure value (Normal)
1 - 99
50
2
MAN-
UAL
Manual exposure value (Nor-
mal)
1 - 99
50