MX-C250 ADJUSTMENTS 5 – 3
DVK:XXX DVC:XXX DVM:XXX DVY:XXX
When the adjustment value (specified value) of the middle speed
mode is set, the adjustment values of the other modes are auto-
matically set according to the middle speed mode setting in a cer-
tain relationship.
NOTE:
Since the high voltage output cannot be checked with a
digital multi meter in this model, a judgment of the output
must be made by checking the print image quality.
1-C
Transfer voltage adjustment
This adjustment is needed in the following situations:
* When the high voltage PWB is replaced.
* U2 trouble has occurred.
1)
Enter the SIM 8-6 mode.
Item/Display
Content
Setting
range
1
M DVB_K
K developing bias set value
at middle speed
0-600
2
M DVB_C
C developing bias set value
at middle speed
0-600
3
M DVB_M
M developing bias set value
at middle speed
0-600
4
M DVB_Y
Y developing bias set value
at middle speed
0-600
5
L DVB_K
K developing bias set value
at low speed
0-600
6
L DVB_C
C developing bias set value
at low speed
0-600
7
L DVB_M
M developing bias set value
at low speed
0-600
8
L DVB_Y
Y developing bias set value
at low speed
0-600
Sim08-06 THV OUTPUT
1.
䠖
TC1
2.
䠖
TC2
㻌 㻌 㻌 㻌
3.
䠖
TC2 CLEAN
㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌 㻌
01
0
㻌