MX-C250 DISASSEMBLY AND ASSEMBLY 10 – 7
G. Development unit
1)
Remove the Toner collection container.
2)
Remove the toner cartridges.
3)
Move the stopper of the developing unit cover inside and
remove the 2 screws. Then, remove the developing unit cover.
Check the home position of the Primary transfer unit. Rotate the
cam counter clockwise.
4)
Disconnect the developing unit connector.
5)
Pull out the developing unit with pressing the lever.
When pulling out and pushing in the developing unit, put your
hand beneath the unit and slide it horizontally along the guide.
When pushing in the developing unit, connect the connector of
the developing unit firmly.
Parts
1