MX-C250 OPERATIONAL DESCRIPTIONS 11 – 4
<JAM detection>
RSPF
SPF
<Single scanning timing figure>
JAM Code
JAM contents
JAM detection method
Basic distance
(A)[mm]
JAM margin dis-
tance(B)[mm]
JAM detection dis-
tance (A+B)[mm]
JAM start trigger
JAM judgement con-
dition
SPPD1_N
SPPD1 not-
reached JAM
Starts the paper feed
SPPD1 ON
99.2
50
149.2
SPPD2_N
SPPD2 not-
reached JAM
SPPD1ON
SPPD2 ON
140.5
50
190.5
SPPD1_NR
SPPD1 reverse
not reached
JAM
Reverse start posi-
tion
SPPD1 ON
111.1
50
161.1
SPPD1_S
SPPD1 remain-
ing JAM
SPPD1ON
SPPD1 OFF
Normal mode :
355.6mm
Long paper
mode(FAX) :
500mm
50
Normal mode : 405.6mm
Long paper(FAX) :
550mm
SPPD1_SR
SPPD1 reverse
remaining JAM
SPPD1ON
SPPD1 OFF
355.6
50
405.6
SPPD2_S
SPPD2 remain-
ing JAM
SPPD1 OFF
SPPD2 OFF
141.1
50
191.1
P_SHORT
Short size JAM
SPPD1 OFF
When the paper length
is less than 69.0mm on
the single scanning
When the paper length
is less than 159.4mm
on the 2-sided scan-
ning
-
-
-
JAM Code
JAM contents
JAM detection method
Basic distance
(A)[mm]
JAM margin dis-
tance(B)[mm]
JAM detection dis-
tance (A+B)[mm]
JAM start trigger
JAM judgement con-
dition
SPPD1_N
SPPD1 not-
reached JAM
Starts the paper feed
SPPD1 ON
99.2
50
130.5
SPPD1_S
SPPD1 remain-
ing JAM
SPPD1ON
SPPD1 OFF
Normal mode :
355.6mm
Long paper
mode(FAX) :
500mm
50
Normal mode : 405.6mm
Long paper(FAX) :
550mm
P_SHORT
Short size JAM
SPPD1 OFF
When the paper length
is less than 114.1mm
-
-
-
100ms
100ms
1000ms
1000ms
190.3mm
190.3mm
204.6mm
204.6mm
50ms
50ms
50ms
50ms
255mm
255mm
SPUFSPUF
SPPD1SPPD1
ON/OFFON/OFF
6179ms
6179ms
Reverse pulse
Reverse pulse
(15mm minutes)
(15mm minutes)
SPFM
SPFM
SPFM tranportation motor
SPFM tranportation motor
SPPD1
SPPD1
SPF transportation sensor
SPF transportation sensor
SRVC
SRVC
Reverse clutch
Reverse clutch
SPUS
SPUS
SPF paper feed solenoid
SPF paper feed solenoid
Reading positoin
Reading positoin
Pickup roller is returned by the reverse rotation
Pickup roller is returned by the reverse rotation
after finishing the job JOB.
after finishing the job JOB.
This is ON in 190.3mm after SPPD1_ON.
This is ON in 190.3mm after SPPD1_ON.
This is OFF in 204.6mm after SPPD1_OFF.
This is OFF in 204.6mm after SPPD1_OFF.
(Only the last paer is OFF in 225.0mm)
(Only the last paer is OFF in 225.0mm)
Moter is stopped in 255mm transportation
Moter is stopped in 255mm transportation
after the last paper passes SPPD1.
after the last paper passes SPPD1.