MX-C250 SIMULATION 6 – 53
*1: The color image skew adjustment is performed according to this
display value.
When "R" is displayed in front of the value, turn and click the skew
adjustment screw (LSU) clockwise by the value.
When "L" is displayed in front of the value, turn and click the skew
adjustment screw (LSU) counterclockwise by the value.
At that time, the values under the decimal point are rounded.
<Error displays in case of abnormal end >
Error
code
Error
display
Error
content
Description
Forcible
end error
-
INTER-
RUP-
TION
Door open
end
Door open during operation
-
INTER-
RUP-
TION
Stop but-
ton end
CA button pressed during
operation
-
-
OFF end
Unconfirmed operation during
operation
Basic error
1
TON-
NER
EMPTY
01
Toner
Empty
BK or ALL Color toner
EMPTY detection
2
BEFOR
BEHAV-
IOR 02
Other con-
dition
Other condition
4
SEN-
SOR
CALIB-
LATION
F 04
Calibra-
tion error
The target is not reached by 3
times of retry of F or R
5
SEN-
SOR
CALIB-
LATION
R 05
Calibra-
tion error
R
6
SEN-
SOR
CALIB-
LATION
FR 06
Calibra-
tion error
FR
7
TIME
OVER
07
Time error
No data is received for 90
sec. after receiving the previ-
ous data.
8
PRO-
CESS
CON-
TROL 08
Process
control
error
Process control error detec-
tion
Sub scan-
ning
adjust-
ment error
10
DATA_S
UB_K_F
_all 10
Data num-
ber error
There is no pitch data.
Sub scan-
ning direc-
tion BK F
side
11
DATA_S
UB_K_F
_any 11
Data num-
ber error
The pitch data number are
not the specified value.
Sub scan-
ning direc-
tion BK F
side
15
DATA_S
UB_K_R
_all 15
Data num-
ber error
There is no pitch data.
Sub scan-
ning direc-
tion BK R
side
16
DATA_S
UB_K_R
_any 16
Data num-
ber error
The pitch data number are
not the specified value.
Sub scan-
ning direc-
tion BK R
side
20
DATA_S
UB_C_F
_all 20
Data num-
ber error
There is no pitch data.
Sub scan-
ning direc-
tion CY F
side
Sub scan-
ning
adjust-
ment error
21
DATA_S
UB_C_F
_any 21
Data num-
ber error
The pitch data number are
not the specified value.
Sub scan-
ning direc-
tion CY F
side
25
DATA_S
UB_C_R
_all 25
Data num-
ber error
There is no pitch data.
Sub scan-
ning direc-
tion CY R
side
26
DATA_S
UB_C_R
_any 26
Data num-
ber error
The pitch data number are
not the specified value.
Sub scan-
ning direc-
tion CY R
side
30
DATA_S
UB_M_F
_all 30
Data num-
ber error
There is no pitch data.
Sub scan-
ning direc-
tion MG F
side
31
DATA_S
UB_M_F
_any 31
Data num-
ber error
The pitch data number are
not the specified value.
Sub scan-
ning direc-
tion MG F
side
35
DATA_S
UB_M_
R_all 35
Data num-
ber error
There is no pitch data.
Sub scan-
ning direc-
tion MG F
side
36
DATA_S
UB_M_
R_any
36
Data num-
ber error
The pitch data number are
not the specified value.
Sub scan-
ning direc-
tion MG R
side
40
DATA_S
UB_Y_F
_all 40
Data num-
ber error
There is no pitch data.
Sub scan-
ning direc-
tion YE F
side
41
DATA_S
UB_Y_F
_any 41
Data num-
ber error
The pitch data number are
not the specified value.
Sub scan-
ning direc-
tion YE F
side
45
DATA_S
UB_Y_R
_all 45
Data num-
ber error
There is no pitch data.
Sub scan-
ning direc-
tion YE R
side
46
DATA_S
UB_Y_R
_any 46
Data num-
ber error
The pitch data number are
not the specified value.
Sub scan-
ning direc-
tion YE R
side
Main
scanning
adjust-
ment error
50
DATA_M
AIN_K_
F_all 50
Data num-
ber error
There is no pitch data.
Main
scanning
direction
BK F side
51
DATA_M
AIN_K_
F_any
51
Data num-
ber error
The pitch data number are
not the specified value.
Main
scanning
direction
BK F side
Error
code
Error
display
Error
content
Description