MX-C250 SIMULATION 6 – 38
44-14
Purpose
Operation data display
Function (Purpose)
Used to display the output level of the tem-
perature and humidity sensor.
Section
Process (OPC drum, development)/Fusing/
LSU
Operation/Procedure
The output levels of the fusing temperature sensor, the machine
temperature sensor, and the humidity sensor are displayed.
* above AD values are changed to hexadecimal
44-15
Purpose
Operation data display
Function (Purpose)
Used to set the OPC drum idle rotation.
Section
Developing system
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
NOTE:
Set the items to the default values unless a change is spe-
cially required.
PATCH
18/
23
Y1
High density
process control
patch data 4_Y1
0 - 255
0
Y2
High density
process control
patch data 4_Y2
0 - 255
0
Y3
High density
process control
patch data 4_Y3
0 - 255
0
Y4
High density
process control
patch data 4_Y4
0 - 255
0
19/
23
Bk_BASE
5
High density
process control
patch data
5_K1_BASE
0 - 255
0
CL_BASE
5
High density
process control
patch data
5_C1_BASE
0 - 255
0
K1
High density
process control
patch data 5_K1
0 - 255
0
K2
High density
process control
patch data 5_K2
0 - 255
0
20/
23
K3
High density
process control
patch data 5_K3
0 - 255
0
K4
High density
process control
patch data 5_K4
0 - 255
0
C1
High density
process control
patch data 5_C1
0 - 255
0
C2
High density
process control
patch data 5_C2
0 - 255
0
21/
23
C3
High density
process control
patch data 5_C3
0 - 255
0
C4
High density
process control
patch data 5_C4
0 - 255
0
M1
High density
process control
patch data
5_M1
0 - 255
0
M2
High density
process control
patch data
5_M2
0 - 255
0
22/
23
M3
High density
process control
patch data
5_M3
0 - 255
0
M4
High density
process control
patch data
5_M4
0 - 255
0
Y1
High density
process control
patch data 5_Y1
0 - 255
0
Y2
High density
process control
patch data 5_Y2
0 - 255
0
23/
23
Y3
High density
process control
patch data 5_Y3
0 - 255
0
Y4
High density
process control
patch data 5_Y4
0 - 255
0
Mode
Page
Item
Content
Range
Default
Value
ITEM
CONTENT
Range
Default
value
TH_UM
(deg)
Fusing main thermistor
detection temperature
(Temperature degrees C)
Temperature 0 -
255degrees C(+/-
1degrees C)
Measured
value
TH_UM_AD
(hex)
Fusing main thermistor dif-
ferential input AD value
(AD value)
AD value 0 - 1023
Measured
value
TH_UM_AD
1(deg)
Fusing main thermistor
compensation sensor tem-
perature (Temperature
degrees C)
Temperature 0.0 -
255.0degrees
C(+/-0.1degrees
C)
Measured
value
TH_UM_AD
1(hex)
Fusing main thermistor
compensation sensor, AD
value V
AD value 0 - 1023
Measured
value
TH_UM_AD
2(hex)
Fusing main thermister
detection sensor AD value
(AD value)
AD value 0 - 1023
Measured
value
TH_US(deg)
Fusing sub thermistor
detection temperature
(Temperature degrees C)
Temperature 0 -
255degrees C(+/-
1degrees C)
Measured
value
TH_US_AD(
hex)
Fusing sub thermistor AD
input value (AD value)
AD value 0 - 1023
Measured
value
TH_M(deg)
Multipurpose tray tempera-
ture sensor AD value (Tem-
perature degrees C)
Temperature -
40.0degrees C -
150.0(+/-
0.1degrees C)
Measured
value
TH_M_AD(h
ex)
Multipurpose tray tempera-
ture sensor AD value (AD
value)
AD value 0 - 1023
Measured
value
HUD_M(%)
Multipurpose tray humidity
sensor AD value (Humidity
%)
Humidity 0.0 -
100.0%(+/-0.1%)
Measured
value
HUD_M_AD
(hex)
Multipurpose tray humidity
sensor AD value (AD
value)
AD value 0 - 1023
Measured
value
TH1_LSU(d
eg)
LSU thermistor 1 AD value
(Temperature degrees C)
Temperature 0.0 -
255.0degrees
C(+/-1degrees C)
Measured
value
TH1_LSU_A
D(hex)
LSU thermistor 1 AD value
(AD value)
AD value 0 - 255
Measured
value
ITEM
CONTENT
RANGE
TIME
Idle rotation interval (time interval between the previ-
ous OPC drum idle rotation and the next one) setting
(h)
0 - 255
AREA1
Environmental area difference judgment threshold
value setting (difference between the previous OPC
drum idle rotation and the current one)
0 - 5
AREA2
Environmental area conditions (AND condition of the
previous OPC drum idle rotation and the current one)
1 - 15
CYCL
E
Previous rotation time setting (sec) in the process
control when recovered from power ON, preheating /
sleep mode.
0 - 255