MX-C250 SIMULATION 6 – 83
109
1 - 3
Delayed time from ANSam detec-
tion
1.0s
0 0 0
1.5s
0 0 1
2.0s
0 1 0
2.5s
0 1 1
3.0s
1 0 0
3.5s
1 0 1
4.0s
1 1 0
4.5s
1 1 1
4 - 5
Not used
6
Measure the communication time
(Image)
0 : OFF
1 : ON
7 - 8
Not used
110 -
111
Not used
112
1, 2
CNG send starting time
0.5s
0 0
1.0s
0 1
1.5s
1 0
3, 4
RCP send number
3 times
0 0
6 times
0 1
9 times
1 0
12 times
1 1
5, 6
V.34 retrain PPR number when
sending
Does not retrain
0 0
1 times
0 1
2 times
1 0
3 times
1 1
7, 8
CI send number to move to non-
V.34 communication
Does not retrain
0 0
1 times
0 1
2 times
1 0
3 times
1 1
113
1
FAX initial setting/
Adjustment value
Super G3 invalid when the last call
is re-sent at error
0 : Super G3 invalid
1 : Super G3 valid
2
FAX initial setting
Prohibit/Permit the re-call of direct
send
0 : Prohibited
1 : Permitted
3, 4
Waiting time for starting sending
G3
4.5s
0 0
5.0s
0 1
6.0s
1 0
7.0s
1 1
5
Operation when receiving EER
flame
0 : Does not continue opera-
tion
1 : Continue operation
6 - 8
Not used
114 -
115
Not used
116
1, 2
Line error ratio of RTN sending
6line
0 0
12line
0 1
60line
1 0
120line
1 1
3, 4
Waiting time of CED starting send-
ing
2.25s
0 0
3s
0 1
4s
1 0
5, 6
Waiting time of ANSam starting
sending
2.25s
0 0
3s
0 1
4s
1 0
7, 8
Not used
117
1 - 8
ANSam and CED Transmit Power
Level Adjustment.
Not used at this moment
Two states input
118
1, 2
CI send number to move to non-
V.34 communication
Does not move
0 0
1 times
0 1
2 times
1 0
3 times
1 1
3, 4
V.34 retrain PPR number when
receiving
Data ratio : More than 16800bps
Does not retrain
0 0
1 times
0 1
2 times
1 0
3 times
1 1
5, 6
V.34 retrain PPR number when
receiving
Data ratio : More than 14400bps
Does not retrain
0 0
1 times
0 1
2 times
1 0
3 times
1 1
7
Primary channel fall back when
V.34 is received
0 : Does not fall back
1 : Fall back
8
Not used
SW
No.
Bit
No.
System set-
tings
Item
SW selection and function
Remarks