MX-C250 SIMULATION 6 – 4
26
6
Used to set the specifications (paper, fixed magnification ratio, etc.) of the destination.
18
Used to set Disable/Enable of the toner save mode operation. (For the Japan and the UK versions.)
30
Used to set the operation mode corresponding to the CE mark (Europe safety standards). (For slow start to
drive the fusing heater lamp)
35
Used to set the display mode of SIM 22-4 trouble history when a same trouble occurred repeatedly. There are
two display modes: display as one trouble and display as several series of troubles.
38
Used to set Continue/Stop of print when the maintenance life is reached.
53
User auto color calibration (color balance adjustment) Inhibit/Allow setting (copy mode)
54
User auto color calibration (color balance adjustment) Inhibit/Allow setting (printer mode)
69
Used to set the operating conditions for toner near end.
73
Used to set Toner save setting.
27
2
Used to set the sender's registration number and the HOST server telephone number. (FSS function)
4
Used to set the initial call and toner order auto send. (FSS function)
7
Used to set of the enable, alert callout. (FSS function)
14
Used to set the FSS function connection test mode.
15
Used to display the FSS connection status.
16
Used to set the FSS alert send.
30
1
Used to check the operations of the sensors and the detectors in other than the paper feed section and the
control circuits.
43
1
Used to set the fusing reference temperature of each operation mode.
4
Used to set the fusing temperature 2 in each mode. (Continued from SIM 43-1.)
20
Used to set the environmental correction under low temperature and low humidity (L/L) for the fusing temper-
ature setting (SIM 43-1) in each paper mode.
21
Used to set the environment correction under high temperature and high humidity (H/H) for the fusing tem-
perature setting (SIM 43-1) in each paper mode.
22
Used to set the environment correction under low temperature and low humidity (L/L) for the fusing tempera-
ture setting (SIM 43-4) in each paper mode.
23
Used to set the environment correction under high temperature and high humidity (H/H) for the fusing tem-
perature setting (SIM 43-4) in each paper mode.
24
Used to set the correction of the temperature adjustment value of SIM 43-1 and 43-4.
44
1
Used to set each correction operation function in the image forming (process) section.
Image process (Photoconductor/
Developing/Transfer/Cleaning)
2
Used to adjust the sensitivity of the image density sensor (registration sensor).
Process
4
Used to set the conditions of the high density process control operation.
Process
6
Used to execute the high density process control forcibly.
Process
9
Used to display the result data of the high density process control operation.
Image process (Photoconductor/
Developing/Transfer/Cleaning)
12
Used to display the operation data of the high density process control and the image density sensor (registra-
tion sensor).
Image process (Photoconductor/
Developing)
14
Used to display the output level of the temperature and humidity sensor.
Process (OPC drum, develop-
ment)/Fusing/LSU
15
Used to display the toner density control data.
Developing system
21
Used to set the half tone process control target.
Process
22
Used to display the toner patch density level in the half tone process control operation.
Process
24
Used to display the correction target and the correction level in the half tone process control operation.
Process
25
Used to set the calculating conditions of the correction value for the half tone process control.
Process
26
Used to execute the half tone process control compulsorily.
Process
27
Used to clear the correction data of the half tone process control.
Process
28
Used to set the process control execution conditions.
Process
29
Used to set the operating conditions of the process control during a job.
Process
31
Used to adjust the OPC drum phase. (Manual adjustment)
Process
37
Used to set the development bias correction level in the continuous printing operation.
43
Used to display the identification information of the developing unit.
Developing system
62
Used to set the calibration data of the color image sensor (image registration sensor F).
Main
Sub
Functions
Section