MX-C250 SIMULATION 6 – 51
50-10
Purpose
Adjustment
Function (Purpose)
Used to adjust the black print image magni-
fication ratio and the off-center position.
(The adjustment is made separately for
each paper feed section.)
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
Item 1: When the set value is increased, the BK image magnifica-
tion ratio in the main scanning direction is increased. When the set
value is decreased, the image magnification ratio is decreased.
Item 2 - 7: When the adjustment value is increased, it is shifted to
the front frame side. When the adjustment value is decreased, it is
shifted to the rear frame side.
Item 2 - 7: 1 step = 0.1mm change
50-12
Purpose
Adjustment
Function (Purpose)
Used to perform the scan image off-center
position adjustment. (The adjustment is
made separately for each scan mode.)
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
When the adjustment value is increased, the image position is
shifted to the rear frame side. When the adjustment value is
decreased, it is shifted to the front frame side.
1step = 0.1mm
50-20
Purpose
Adjustment
Function (Purpose)
Image registration adjustment
(Manual adjustment)
Section
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
Item/Display
Content
Setting range
Default
value
NOTE
1
BK-MAG
Main scan print magnification ratio BK
60 - 140
110
Adjustment Item List
2
MAIN-MFT
Print off center adjustment value
(Manual paper feed)
1 - 99
65
3
MAIN-CS1
Print off center adjustment value (Tray 1)
1 - 99
65
4
MAIN-CS2
Print off center adjustment value (Tray 2)
1 - 99
50
5
MAIN-ADU
Print off center adjustment value (Duplex)
(NOTE) If the adjustment items A - F are
not properly adjusted, this adjustment can-
not be executed properly.
1 - 99
50
6
SUB-MFT
Resist motor ON
timing adjustment
Manual paper feed
1 - 99
60
7
SUB-CS1
Standard cassette
1 - 99
60
8
SUB-DSK
DESK 1
-
99
50
9
SUB-ADU
ADU
1 - 99
50
10
PAPER
MFT
Cassette selection
Manual paper feed
1?3
1
2(CS1)
CS1
Cassette 1
2
CS2
Cassette 2
3
Item/Display
Content
Setting
range
Default
value
1
OC
Document table image off-
center adjustment
1 - 99
50
2
SPF(FRONT)
RSPF front surface image
off-center adjustment
1 - 99
50
3
SPF (Rear)
RSPF back surface image
off-center adjustment
1 - 99
50
Item/Display
Contents
Range
Default
value
1
OFFSET_S
UB_C
Registration adjustment value sub
scanning direction offset value
CYAN
1 - 99
50
2
OFFSET_M
AIN_C_F
Registration adjustment value
main scanning direction offset
value CYAN (FRONT)
1 - 99
50
3
OFFSET_M
AIN_C_R
Registration adjustment value
main scanning direction offset
value CYAN (REAR)
1 - 99
50
4
OFFSET_S
UB_M
Registration adjustment value sub
scanning direction offset value
MAGENTA
1 - 99
53
5
OFFSET_M
AIN_M_F
Registration adjustment value
main scanning direction offset
value MAGENTA (FRONT)
1 - 99
50
6
OFFSET_M
AIN_M_R
Registration adjustment value
main scanning direction offset
value MAGENTA (REAR)
1 - 99
50
7
OFFSET_S
UB_Y
Registration adjustment value sub
scanning direction offset value
YELLOW
1 - 99
53
8
OFFSET_M
AIN_Y_F
Registration adjustment value
main scanning direction offset
value YELLOW (FRONT)
1 - 99
50
9
OFFSET_M
AIN_Y_R
Registration adjustment value
main scanning direction offset
value YELLOW (REAR)
1 - 99
50