MX-C250 SIMULATION 6 – 54
Main
scanning
adjust-
ment error
55
DATA_M
AIN_K_
R_all 55
Data num-
ber error
There is no pitch data.
Main
scanning
direction
BK R side
56
DATA_M
AIN_K_
R_any
56
Data num-
ber error
The pitch data number are
not the specified value.
Main
scanning
direction
BK R side
60
DATA_M
AIN_C_
F_all 60
Data num-
ber error
There is no pitch data.
Main
scanning
direction
CY F side
61
DATA_M
AIN_C_
F_any
61
Data num-
ber error
The pitch data number are
not the specified value.
Main
scanning
direction
CY F side
65
DATA_M
AIN_C_
R_all 65
Data num-
ber error
There is no pitch data.
Main
scanning
direction
CY R side
66
DATA_M
AIN_C_
R_any
66
Data num-
ber error
The pitch data number are
not the specified value.
Main
scanning
direction
CY R side
70
DATA_M
AIN_M_
F_all 70
Data num-
ber error
There is no pitch data.
Main
scanning
direction
MG F side
71
DATA_M
AIN_M_
F_any71
Data num-
ber error
The pitch data number are
not the specified value.
Main
scanning
direction
MG F side
75
DATA_M
AIN_M_
R_all 75
Data num-
ber error
There is no pitch data.
Main
scanning
direction
MG R side
76
DATA_M
AIN_M_
R_any
76
Data num-
ber error
The pitch data number are
not the specified value.
Main
scanning
direction
MG R side
80
DATA_M
AIN_Y_
F_all 80
Data num-
ber error
There is no pitch data.
Main
scanning
direction
YE F side
81
DATA_M
AIN_Y_
F_any
81
Data num-
ber error
The pitch data number are
not the specified value.
Main
scanning
direction
YE F side
85
DATA_M
AIN_Y_
R_all 85
Data num-
ber error
There is no pitch data.
Main
scanning
direction
YE R side
Error
code
Error
display
Error
content
Description
Main
scanning
adjust-
ment erro
86
DATA_M
AIN_Y_
R_any
86
Data num-
ber error
The pitch data number are
not the specified value.
Main
scanning
direction
YE R side
Sub scan-
ning
adjust-
ment error
91
RANGE
_SUB_C
91
Adjust-
ment
value
error
The calculation result value is
not within the allowable
range.
Sub scan-
ning direc-
tion CY R
side
93
RANGE
_SUB_M
93
Adjust-
ment
value
error
Sub scan-
ning direc-
tion MG
95
RANGE
_SUB_Y
95
Adjust-
ment
value
error
Sub scan-
ning direc-
tion YE
Main
scanning
adjust-
ment error
97
RANGE
_MAIN_
C_F 97
Adjust-
ment
value
error
Main
scanning
direction
CY R side
99
RANGE
_MAIN_
C_R 99
Adjust-
ment
value
error
Main
scanning
direction
CY R side
101
RANGE
_MAIN_
M_F 101
Adjust-
ment
value
error
Sub scan-
ning direc-
tion MG F
side
103
RANGE
_MAIN_
M_R 103
Adjust-
ment
value
error
Main
scanning
direction
MG F side
105
RANGE
_MAIN_
Y_F 105
Adjust-
ment
value
error
Adjust-
ment
value
error
Main
scanning
adjust-
ment error
107
RANGE
_MAIN_
Y_R 107
Adjust-
ment
value
error
Main
scanning
direction
YE R side
Error
code
Error
display
Error
content
Description