MX-C250 SIMULATION 6 – 10
8
8-1
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operations of
the developing voltage in each print mode
and the control circuit.
* When the middle speed is adjusted, the
low speed is also adjusted simultaneously.
Section
Process (Developing)
Operation/Procedure
1) Select the process speed with 10 keys.
2) Select a target item to be adjusted with Arrow keys.
3) Enter the setting value with 10 keys. (The value specified on the
label of the high voltage PWB must be entered.)
* When the Arrow key is pressed, the setting value of each
item can be changed with 1up (1down) collectively.
4) Press [OK]/[START] key.
When [EXECUTE] key is pressed, the voltage inputted in pro-
cedure 3 is outputted for 30sec and the set value is saved.
When [EXECUTE] key is pressed, the output is terminated.
8-2
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operation of
the main charger grid voltage in each
printer mode and the control circuit.
* When the middle speed is adjusted, the
low speed are also adjusted simultane-
ously.
Section
Process (Charging)
Operation/Procedure
1) Select the process speed.
2) Select a target item to be adjusted with Arrow keys.
3) Enter the adjustment value with 10 keys. (The value specified
on the label of the high voltage PWB must be entered.)
* When the Arrow key is pressed, the setting value of each
item can be changed with 1up (1down) collectively.
4) Press [OK]/[START] key.
When [EXECUTE] key is pressed, the voltage inputted in pro-
cedure 3 is outputted for 30sec and the set value is saved.
When [EXECUTE] key is pressed, the output is terminated.
No.
Item/Dis-
play
Content
Setting
range
Volt
age
1
M DVB_K
K developing bias set value at
middle speed
0-600
450
2
M DVB_C
C developing bias set value at
middle speed
0-600
450
3
M DVB_M
M developing bias set value at
middle speed
0-600
450
4
M DVB_Y
Y developing bias set value at
middle speed
0-600
450
5
L DVB_K
K developing bias set value at low
speed
0-600
450
6
L DVB_C
C developing bias set value at low
speed
0-600
450
7
L DVB_M
M developing bias set value at low
speed
0-600
450
8
L DVB_Y
Y developing bias set value at low
speed
0-600
450
No.
Item/
Display
Content
Setting
range
Default
setting
1
M GB_K
K grid bias set value at middle speed
150-850
630
2
M GB_C
C grid bias set value at middle speed
150-850
630
3
M GB_M
M grid bias set value at middle speed
150-850
630
4
M GB_Y
Y grid bias set value at middle speed
150-850
630
5
L GB_K
K grid bias set value at low speed
150-850
615
6
L GB_C
C grid bias set value at low speed
150-850
595
7
L GB_M
M grid bias set value at low speed
150-850
595
8
L GB_Y
Y grid bias set value at low speed
150-850
595
No.
Item/
Display
Content
Setting
range
Default
setting