Connecting encoders to the basic unit
Installation
4.12 Connecting encoders to the basic unit
Example
For the pin assignment, refer to sec. 4.11 "Terminal assignment", paragraph "Terminal
assignment of MXA axis modules".
NOTES
The core colors specified in the wiring diagrams are in accordance with IEC 757 and
correspond to the core colors used in the pre-fabricated cables from SEW-
EURODRIVE.
You will find detailed information in the "SEW encoder systems" manual. The manual
is available from SEW-EURODRIVE.
View of the flange sockets in a servomotor
View connection motor
encoder to axis module
58364AXX
53934AXX
[1]
Power connection
[2]
Encoder connection
9
8
7
6
5
4
11
12
10
3
P
[1]
[2]
15
9
1
8
WARNING
Dangerous contact voltages at the unit terminals when connecting the wrong temper-
ature sensors.
Severe or fatal injuries from electric shock.
• Connect only temperature sensors with reliable isolation from the motor winding to
the temperature evaluation. Otherwise, the requirements for reliable isolation are
not met. Dangerous contact voltages may occur at the unit terminals via the signal
electronics in case of an error.