6
Operating displays and errors of MXA axis module
Operation
6.4
Operating displays and errors of MXA axis module
Table of displays
Description
State
Comment / action
Displays during boot process
Unit passes through several
states when loading the firm-
ware (boot) to get ready for
operation.
•
Status: not ready.
•
Output stage is blocked.
•
No communication possible.
•
Waiting for boot process to finish.
•
Unit stays in this condition: Unit defective.
Displays of diverse unit statuses
No DC link voltage.
•
Status: not ready.
•
Output stage is blocked.
•
Communication is possible.
Check mains.
Supply module not ready for
operation.
Check supply module.
Axis module 24 V or internal
switched-mode power supply
module of axis not ready for
operation.
24 V check or unit defective.
Flashing
Axis module in safe stop.
Safety function activated.
Synchronization with bus is
incorrect. Process data pro-
cessing not available.
•
Check bus connection.
•
Check synchronization setting at unit and
control.
•
Check process data settings at unit and con-
trol.
•
Check missing of a PDO.
Flashing
The encoder evaluation is not
ready.
•
Encoders are initialized.
•
Unit stays in this condition:
•
No encoder selected.
•
"Source of actual speed" parameter
shows an encoder that does not exist.
Displays during initialization processes (parameters will be reset to default values)
Basic initialization.
•
Status: not ready.
•
Output stage is blocked.
•
Communication is possible.
Waiting for initialization to finish.
Initialization delivery status.
Initialization factory setting.
Initialization customer-specific
set 1.
Initialization customer-specific
set 2.