![SEW MOVIAXIS MX Скачать руководство пользователя страница 155](http://html1.mh-extra.com/html/sew/moviaxis-mx/moviaxis-mx_operating-instructions-manual_1250008155.webp)
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
155
5
PDO Editor
Startup
Assigning the input
buffer to the sys-
tem variables
Next, the words of the IN buffer must be assigned to the control word 1 and the IN pro-
cess data.
In the example, the first word of the IN buffer is assigned the FCB number, the second
word is assigned the speed, and the third word the ramp. You can assign the associated
words using drag & drop.
Setting the FCB
parameters
Clicking "FCB" opens the configuration interface of the FCBs. To being able to control
the speed controller via fieldbus, the setpoint sources for velocity and acceleration val-
ues are set to process data buffer channel 0 or channel 1 in the FCB05.
11830aen
Figure 99: IN process data interface, conversion of internal system variable
11831aen
Figure 100: Overview of FCBs
0