![SEW MOVIAXIS MX Скачать руководство пользователя страница 165](http://html1.mh-extra.com/html/sew/moviaxis-mx/moviaxis-mx_operating-instructions-manual_1250008165.webp)
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
165
6
Operating displays and errors of MXA axis module
Operation
08
Error "Speed
monitoring“
Active speed monitoring has detected
an unacceptable deviation between
setpoint and actual speed
Output stage
inhibit (D), (P)
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
Motor speed monitoring
02
Regenerative speed monitoring
03
System limit actual speed exceeded
11
Error "Overtem-
perature“ axis
module
The temperature of the AM has
reached or exceeded the shutdown
limit. Possible reasons:
•
Ambient temperature too high
•
Unfavorable air convection -
defective fan
•
Medium utilization too high
Shutdown with
emergency stop
delay (D), (P)
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
Limit heat sink temperature
exceeded.
12
Error “Brake
output”
•
No brake connected
•
Brake line separated in 'on' status
•
Overload through overcurrent >
2A (F13 has priority)
•
Overload due to excessive con-
nection (approx. > 0.5 Hz)
Monitoring is only active with parame-
ter settings "Brake installed" and
"Brake applied".
Output stage
inhibit
System is
blocked
System restart
Yes
Ready = 0
Malfunction
= 0
01
Brake output
13
Error "Brake sup-
ply“
Brake supply voltage not within per-
mitted range of +10/- 0%. Monitoring
works with parameter setting "Brake
installed" and "Brake applied" as well
as with CMP and DS motors only.
Output stage
inhibit
System is
blocked
System restart
Yes
Ready = 0
Malfunction
= 0
01
Brake supply voltage
14
Error "Resolver“
Error with resolver or resolver evalua-
tion.
Output stage
inhibit
System is
blocked
System restart
Yes
Ready = 0
Malfunction
= 0
01
Open circuit detection resolver
02
Emulation error resolver (excessive
speed)
19
Non-permissible angle during calibra-
tion
15
Error "Hiperface
Compare Check“
An error has occurred in the check-
sum of the Hiperface signals.
Output stage
inhibit
System is
blocked
System restart
Yes
Ready = 0
Malfunction
= 0
01
Comparison of the absolute encoder
position (via Hiperface parameter
channel) with the incremental position
of the axis every second.
02
Encoder type unknown
32
Encoder signals internal error.
The error code is displayed as fol-
lows: [Displayed value] - 32. You can
inquire about this error code at the
encoder manufacturer.
Error
code
Error message Sub
error
code
Possible reason for error
Error response
(P = programma-
ble,
D = default
response)
Final error
status /
Reset type
Save
as
History
Message
binary out-
puts (valid
for default
response)
Содержание MOVIAXIS MX