![SEW MOVIAXIS MX Скачать руководство пользователя страница 178](http://html1.mh-extra.com/html/sew/moviaxis-mx/moviaxis-mx_operating-instructions-manual_1250008178.webp)
178
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
6
Operating displays of MXC capacitor module component
Operation
6.5
Operating displays of MXC capacitor module component
The operating statuses are indicated by a two-color LED at the front of the housing, see
page 35.
• LED lights up
green
:
– Capacitor module is ready for operation.
• LED lights up
red
:
– General error.
• LED
flashes red
(1 Hz):
– Full utilization of the capacitor module reached.
• LED does not light up:
– No voltage is supplied to the capacitor module.
6.6
Operating displays of MXB buffer module component
No messages are issued at the buffer module.
6.7
Operating displays of 24 V switched-mode power supply module
The operating status, such as utilization and error of the switched-mode power supply,
is indicated by two LEDs on the front of the unit.
• LED State:
– Normal operation
green
.
– Error
red
. A malfunction has occurred because of:
– Overload,
– Overvoltage,
– Undervoltage.
• LED Load:
– Normal operation
green
.
– With ca. 80 % utilization per output (8 A)
yellow
.
57910axx
Figure 103: Operating displays 24 V switched-mode power supply module
[1]
LED State
[2]
LED Load
[1]
[2]