60
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
3
Terminal expansion board type XIA11A option
Unit Design
Parallel connection
of binary outputs
Connecting two binary outputs in parallel doubles the rated current.
This module has
• 2 analog inputs (differential),
• 2 analog outputs,
• 4 binary inputs,
• 4 binary outputs,
• Electrical isolation between binary inputs and outputs as well as electronics.
Terminal
assignment
56942aen
Figure 35: Block diagram for using a free-wheeling diode at the binary output
[1]
Free-wheeling diode
XIA11A
+24V
+24V
0V
0V
DO0
GND_EXT
Load
GND_EXT
GND
GND
Logic
[1]
Designation
Terminal
DCOM
1
X25
COMBICON 5.08
One conductor per terminal:
0.20...2.5 mm
2
Two conductors per terminal:
0.25...1 mm
2
24 V
2
DO 0
3
DO 1
4
DO 2
5
DO 3
6
DI 0
7
DI 1
8
DI 2
9
DI 3
10
Al 0+
1
X26
Al 0-
2
Al 1+
3
Al 1-
4
AO 0
5
AO 1
6
DGND
7
DGND
8