![SEW MOVIAXIS MX Скачать руководство пользователя страница 176](http://html1.mh-extra.com/html/sew/moviaxis-mx/moviaxis-mx_operating-instructions-manual_1250008176.webp)
176
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
6
Operating displays and errors of MXA axis module
Operation
84
Error brake
chopper at AM
Error message through supply mod-
ule via hardware information system.
The brake chopper in the supply
module is not ready for operation,
triggered by BRC short-circuit moni-
toring or driver voltage monitoring.
Output stage
inhibit
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
SM: Error brake chopper
85
Prewarning
“Temperature
monitoring SM”
The temperature of the SM
approaches the cut-off threshold
No response (D),
(P)
---------
Yes
Ready = 1
Malfunction
= 1
01
SM: Temperature prewarning
86
Error "Overtem-
perature SM“
Temperature of the SM has reached
or exceeded the cut-off threshold
Shutdown with
emergency stop
delay (D)
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
SM: Temperature error
87
Prewarning "Utili-
zation braking
resistor in SM“
The utilization of the braking resistor
installed in the SM has reached the
prewarning threshold (applies to
10kW version only)
No response (D),
(P)
---------
Yes
Ready = 1
Malfunction
= 1
01
SM: Ixt prewarning braking resistor
88
Error "Utilization
braking resistor
in SM“
The utilization of the braking resistor
installed in the SM has reached or
exceeded the prewarning threshold
(applies to 10kW version only)
Shutdown with
emergency stop
delay (D)
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
Ixt utilization error braking resistor of
the SM
89
Error "Switched-
mode power sup-
ply SM"
Error Switched-mode power supply
SM
No response
---------
Yes
Ready = 1
Malfunction
= 1
01
At least one of the supply voltages in
the SM is not present
91
Warning "SM
24V voltage sup-
ply“ displayed in
supply module
only
24 V electronics supply less than 17
V -> No error message for the axis !!
No response
---------
Yes
Ready = 1
Malfunction
= 1
01
24 V electronics power supply too low
92
Unassigned
93
Unassigned
94
Error "Unit con-
figuration data"
An error has occurred in the unit con-
figuration data block during testing in
reset phase
Output stage
inhibit
System is
blocked
System restart
Yes
Ready = 0
Malfunction
= 0
01
Unit configuration data: checksum
error
95
Unassigned
96
Unassigned
97
Error "Copy
parameter set"
Parameter set could not be copied
correctly
Output stage
inhibit
System is
blocked
System restart
Yes
Ready = 0
Malfunction
= 0
01
Cancellation of parameter set down-
load to the unit
Error
code
Error message Sub
error
code
Possible reason for error
Error response
(P = programma-
ble,
D = default
response)
Final error
status /
Reset type
Save
as
History
Message
binary out-
puts (valid
for default
response)
Содержание MOVIAXIS MX