![SEW MOVIAXIS MX Скачать руководство пользователя страница 169](http://html1.mh-extra.com/html/sew/moviaxis-mx/moviaxis-mx_operating-instructions-manual_1250008169.webp)
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
169
6
Operating displays and errors of MXA axis module
Operation
25
Error "Non-vola-
tile parameter
memory“
An error was detected during access
to non-volatile parameter memory.
Output stage
inhibit
System is
blocked
System restart
Yes
Ready = 0
Malfunction
= 0
03
Error during read-in of data from non-
volatile memory. The data cannot be
used due to a corrupt identification or
checksum.
04
Initialization error of memory system.
05
The read-only memory contains
invalid data.
06
The read-only memory contains
incompatible data of another device
(in case of exchangeable data memo-
ries)
26
Error "External
terminal“
An error has been reported by a
binary input terminal.
Shutdown with
emergency stop
delay (D), (P)
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
Error external terminal
27
Error "Limit
switch“
One or both limit switches cannot be
detected at the programmed input
terminals or in the control word.
Shutdown with
emergency stop
delay
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
Both limit switches missing or open
circuit
02
Limit switch reversed
28
Process data
timeout error
Process data communication is inter-
rupted.
Shutdown with
application delay
(D), (P)
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
Error fieldbus timeout
29
Error "Approach
hardware limit
switch“
Travel to hardware limit switch during
positioning
Shutdown with
emergency stop
delay (D), (P)
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
Travel to right limit switch
02
Travel to left limit switch
30
Error “Delay
timeout”
The drive did not come to a standstill
within the preset delay time
Output stage
inhibit
System is
waiting
Warm start
Yes
Ready = 1
Malfunction
= 0
01
Stop ramp time violation
02
Time violation stop at application limit
03
Time violation stop at system limit
04
Emergency stop ramp time violation
31
Error "Thermal
protection motor“
Overtemperature sensor
(KTY/TF/TH) of the drive was trig-
gered for motor protection
"No response“ (D),
(P)
No response
Yes
Ready = 1
Malfunction
= 1
01
Open circuit motor temperature sen-
sor detected
02
Short circuit motor temperature sen-
sor detected
03
Motor overtemperature KTY
04
Motor overtemperature (synchro-
nous motor model)
05
Motor overtemperature (TF/TH)
06
Motor overtemperature I2t model
07
AD conversion has not taken place
Error
code
Error message Sub
error
code
Possible reason for error
Error response
(P = programma-
ble,
D = default
response)
Final error
status /
Reset type
Save
as
History
Message
binary out-
puts (valid
for default
response)