Supply module settings for a CAN-based system bus
Startup
5.2
Supply module settings for a CAN-based system bus
The following settings are necessary:
• The CAN baud rate is set using the two DIP switches S1 and S2 on the supply mod-
ule, see sec. "Setting the CAN baud rate".
• The 4 DIP switches for setting the system bus are set to "C".
• The axis address is set using the two address switches S3 and S4 on the supply
module, see sec. "Setting the CAN axis address". The next axis address will be set
automatically based on the first address.
61383axx
Figure 58: DIP switches and axis address switch on the supply module
[1]
DIP switches system bus
[2]
S1, S2: DIP switch for CAN baud rate
[3]
S3: Axis address switch 10
0
[4]
S4: Axis address switch 10
1
[3]
[2]
S1
S2
ON
[4]
5
6
7
4
3
2
1
0
9
8
5
6
7
4
3
2
1
0
9
8
[1]
C
E
S3
S4