![SEW MOVIAXIS MX Скачать руководство пользователя страница 131](http://html1.mh-extra.com/html/sew/moviaxis-mx/moviaxis-mx_operating-instructions-manual_1250008131.webp)
Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
131
5
MOVIAXIS® startup - Single-motor operation
Startup
Monitoring
• Enter the general MOVIAXIS
®
MX control parameters according to the following
table.
11808aen
Figure 84: Menu setting for monitoring
NOTES
The value in the left column of the input menu is a recommendation, while the value in
the right column is the current value of the MOVIAXIS
®
MX multi-axis servo drive.
Click on
• "
→
" buttons to accept individual recommendations,
• "Accept" button to accept all recommendations in one step.
Input data
Description
Speed monitoring and
deceleration time
n-monitoring
The speed required by the setpoint can only be achieved if there is sufficient
torque available to meet the load requirements. Once the current limit has been
reached, the MOVIAXIS
®
MX multi-axis servo drive assumes that the torque
has reached its maximum value. The desired speed cannot be attained. Speed
monitoring is triggered if this situation continues throughout the duration of the
specified
delay n-monitoring
.
Current limit
The current limitation refers to the apparent output current of the multi-axis
servo drive.
0