Operating Instructions – MOVIAXIS® MX Multi-Axis Servo Inverter
137
5
MOVIAXIS® startup - Single-motor operation
Startup
Application and system limits
The application and machine limit values refer to the set user-specified units, see figure
89. The user-specified units selected previously are shown in the illustration and cannot
be altered.
The fields on the right refer to the download value in the axis, converted to the user-
specified unit. The fields on the left are calculated default values.
The following values are the basis for the basic configuration and the delivery status:
11813aen
Figure 90: Application and system limits menu
Variables
Limit values
System limit values (machine limit values)
VmaxSys
10000 1/min, corresponds to the maximum speed possible in the axis module
a_maxSys
3000 1/(min
×
s) acceleration ramp
b_maxSys
3000 1/(min
×
s) deceleration ramp
Application limit values
VmaxApp
10000 1/min, corresponds to the maximum speed possible in the axis module
a_maxApp
3000 1/(min
×
s) acceleration ramp
b_maxApp
3000 1/(min
×
s) deceleration ramp
Emergency stop deceleration
b_maxAppNotStop
3000 1/(min
×
s) deceleration ramp, emergency stop ramp is mainly used for
error response.
0
0