SP LINK | Alert Messages
Doc #OI0005 Rev26 2020
|
107
Alerts and attention
required messages
Meaning and diagnostic
Action
Configuration
settings>
System - Battery Temp
sensor open circuit
There is a fault in the battery
temperature sensor or its wiring.
Contact your installer to check
battery temperature sensor and
its wiring. Measure sensor with
multi meter approximately 2k
ohms at 25C
System - Battery Temp
sensor ok - was open
Above condition has cleared
System - Battery Temp
sensor reading too high
There is a fault in the battery
temperature sensor or its wiring.
Contact your installer to check
battery temperature sensor and
its wiring. Measure sensor with
multi meter approximately 2k
ohms at 25C
System - Battery Temp
sensor ok - was too
high
Above condition has cleared
System - Battery Temp
sensor reading too low
There is a fault in the battery
temperature sensor or its wiring.
Contact your installer to check
battery temperature sensor and
its wiring. Measure sensor with
multi meter approximately 2k
ohms at 25C
System - Battery Temp
sensor ok - was too low
Above condition has cleared
System - Battery Temp
sensor short circuit
There is a fault in the battery
temperature sensor or its wiring.
Contact your installer to check
battery temperature sensor and
its wiring. Measure sensor with
multi meter approximately 2k
ohms at 25C
System - Battery
Temp sensor ok - was
shorted
Above condition has cleared
System - Common
defaults loaded
The user has initiated a “Load Defaults”
from the front panel of the inverter.
System - Hi Battery
Shutdown (AC
Coupled) Fault
Only applies to AC coupled systems
(Managed or Generic). Inverter has
shutdown as a last resort due to high
battery voltage. Inverter only shuts
down if frequency ramping does not
disconnect the AC coupled solar and
the high batter voltage persists.
Contact your installer to check
Grid inverter (Selectronic
Certified or Generic) to see
that it disconnects at 55Hz
grid frequency. If grid inverter
is Selectronic Certified then
check RS485 communications
between the SP PRO and the
grid inverter.
System - Hi Battery
Shutdown (AC
Coupled) Cleared
Above condition has cleared
System - Hi
Temperature Alert
The inverter is reaching its maximum
operating temperature and about to
shut down. Either the load is too high,
the air flow is obstructed or the ambient
temperature is high.
Turn off some of the appliances
connected to the system.
Check fan filter in the base of
the SP PRO for obstructions.
Ensure there is free airflow
around the inverter. If problem
persists, contact your installer.
System - Hi
Temperature Alert
cleared
Above condition has cleared
Содержание SP PRO 2i Series
Страница 1: ...Instruction Manual for SP LINK Configuration and monitoring for SP PRO series 2i ...
Страница 31: ...SP LINK Using SP LINK Doc OI0005 Rev26 2020 31 Blank Page ...
Страница 91: ...SP LINK Performance Monitoring Doc OI0005 Rev26 2020 91 BLANK PAGE ...
Страница 97: ...SP LINK Service Settings Doc OI0005 Rev26 2020 97 Blank Page ...