SP LINK | Performance Monitoring
86
|
Doc #OI0005 Rev26 2020
When DRM is enabled then the currently asserted DRM is highlighted in
the Active DRM display.
Active DRM Export Limit shows, in percent the limit placed by the
currently asserted DRM on the Export Power of the SP PRO. Only DRM
5 to DRM 8 effect the Active DRM Export Limit.
Active DRM Support Limit shows, in percent the limit placed by the
currently asserted DRM on the amount of power that the SP PRO can
use from the grid to charge the battery bank. Only DRM 1 to DRM 4
effect the Active DRM Support Limit.
Generation Management Export Target shows, in percent the
amount of export power that the SP PRO must generate to remain
within the ramp rate limits of the
Generation Management Mode
.
The AC Solar panels (#1 through to #5 when connected) display all of
the data fed back from each Managed AC coupled grid connect unit.
The “RS485 Device Address” shows the Address that has been
configured in that particular grid inverter. For KACO or Fronius inverters
this is address 1 to 5 for AC Solar #1 to AC Solar #5 respectively. For
ABB inverters the RS485 Device address is 2 to 6 respectively.
When ABB solar grid inverters are connected to the SP PRO, there are
4 readings that are not available from the ABB solar gird inverter. AC
Energy today, AC current, DC power and DC current.
When Fronius solar grid inverters are connected to the SP PRO, there
are 7 readings that are not available from the Fronius solar gird inverter.
AC Energy today, AC Volts, AC current, DC power, DC Volts, DC
current and Temperature.
If the SP PRO has lost communications with a grid inverter or the grid
inverter has gone to “sleep” at night, the message “Inverter Offline” is
displayed in all its readings except AC Power Peak Today
Содержание SP PRO 2i Series
Страница 1: ...Instruction Manual for SP LINK Configuration and monitoring for SP PRO series 2i ...
Страница 31: ...SP LINK Using SP LINK Doc OI0005 Rev26 2020 31 Blank Page ...
Страница 91: ...SP LINK Performance Monitoring Doc OI0005 Rev26 2020 91 BLANK PAGE ...
Страница 97: ...SP LINK Service Settings Doc OI0005 Rev26 2020 97 Blank Page ...