78 - 140
Fault Tracking
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
BIT11 BIT10
5
00
01
10
11
BIT13 BIT12
6
00
01
10
11
BIT15 BIT14
7
00
01
10
11
P10.35
BIT1
BIT0
8
00
01
10
11
BIT3
BIT2
9
00
01
10
11
BIT5
BIT4
10
00
01
10
11
BIT7
BIT6
11
00
01
10
11
BIT9
BIT8
12
00
01
10
11
BIT11 BIT10
13
00
01
10
11
BIT13 BIT12
14
00
01
10
11
BIT15 BIT14
15
00
01
10
11
After the users select the corresponding ACC/DEC time, the
combining 16 binary bit will change into decimal bit, and then
set the corresponding function codes.
Setting range: 0x0000~0xFFFF
P10.36
PLC restart
mode
0: Restart from the first stage
. Stop during running (cause
by the stop command, fault or power loss), run from the first
stage after restart.
1: Continue to run from the stop frequency
; stop during
running (cause by stop command or fault), the inverter will
record the running time automatically, enter into the stage after
restart and keep the remaining running at the setting frequency.
0
◎
P10.37
Multi-step time
unit selection
0: Seconds
; the running time of all stages is counted by
second
1: Minutes
; the running time of all stages is counted by
minutes
0
◎
P11 Group Protective parameters