24 - 140
Keypad Operation Procedure
No.
Name
Description
5 Buttons
Programming
key
Enter or escape from the first level menu and remove
the parameter quickly
Entry key
Enter the menu step-by-step
Confirm parameters
UP key
Increase data or function code progressively
DOWN key
Decrease data or function code progressively
Right-shift key
Move right to select the displaying parameter
circularly in stopping and running mode.
Select the parameter modifying digit during the
parameter modification
Run key
This key is used to operate on the inverter in key
operation mode
Stop/
Reset key
This key is used to stop in running state and it is
limited by function code P07.04
This key is used to reset all control modes in the fault
alarm state
Quick key
The function of this key is confirmed by function code
P07.02.
6
Keypad
port
External keypad port. When the external keypad with the function of parameter
copying is installed, the local keypad LED is off; When the external keypad without
the function of parameter copying is installed, the local and external keypad LEDs
are on.
4.2 Keypad displaying
The keypad displaying state of CV30 inverters is divided into stopping state parameter, running state
parameter, function code parameter editing state and fault alarm state and so on.
4.2.1 Displayed state of stopping parameter
When the inverter is in the stopping state, the keypad will display stopping parameters which is shown in
figure 4-2.
In the stopping state, various kinds of parameters can be displayed. Select the parameters to be displayed or
not by P07.07. See the instructions of P07.07 for the detailed definition of each bit.
In the stopping state, there are 14 stopping parameters can be selected to be displayed or not. They are: set
frequency, bus voltage, input terminals state, output terminals state, PID given, PID feedback, torque set
value, AI1, AI2, AI3, HDI, PLC and the current stage of multi-step speeds, pulse counting value, length value.
P07.07 can select the parameter to be displayed or not by bit and
》
/SHIFT can shift the parameters form left
to right, QUICK/JOG (P07.02=2) can shift the parameters from right to left.