50 - 140
Fault Tracking
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
BIT8
BIT7
BIT6
BIT5
BIT4
HDI
S8
S7
S6
S5
BIT3
BIT2
BIT1
BIT0
S4
S3
S2
S1
The setting range: 0x000~0x1FF
P05.11
Switch filter
time
Set the sample filter time of S1~S4 and HDI terminals. If the
interference is strong, increase the parameter to avoid wrong
operation.
0.000~1.000s
0.010s
○
P05.12
Virtual
terminals
setting
0x000~0x1FF (
0: Disabled, 1:Enabled
)
BIT0:
S1 virtual terminal
BIT1:
S2 virtual terminal
BIT2:
S3 virtual terminal
BIT3:
S4 virtual terminal
BIT4:
S5 virtual terminal
BIT5:
S6 virtual terminal
BIT6:
S7 virtual terminal
BIT7:
S8 virtual terminal
BIT8:
HDI virtual terminal
0x000
◎
P05.13
Terminals
control running
mode
Set the operation mode of the terminals control
0: 2-wire control 1. Comply the enable with the direction. This
mode is widely used. It determines the rotation direction by
the defined FWD and REV terminals command.
FWD
REV
COM
K1
K2
Running
command
FWD
REV
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Stopping
Hold on
Forward
running
Reverse
running
1: 2-wire control 2. Separate the enable from the direction.
FWD defined by this mode is the enabling ones. The
direction depends on the state of the defined REV.
0
◎
Содержание CV30