Function Parameters
47 - 140
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
Setting range: 0.0~200.0%
P04.10
Low frequency
vibration
control factor
In the SVPWM control mode, current fluctuation may occur to the
motor on some frequency, especially the motor with big power.
The motor can not run stably or overcurrent may occur. These
phenomena can be canceled by adjusting this parameter.
The setting range of P04.10: 0~100
The setting range of P04.11: 0~100
The setting range of P04.12: 0.00Hz~P00.03(the Max.
frequency)
10
○
P04.11
High frequency
vibration
control factor
10
○
P04.12
Vibration
control
threshold
30.00
Hz
○
P04.26
Energy-saving
operation
selection
0: No operation
1: Automatic energy-saving operation
Motor on the light load conditions, automatically adjusts the
output voltage to save energy
0
◎
P04.27
Voltage Setting
channel
Select the output setting channel at V/f curve separation.
0:
Keypad setting voltage. The output voltage is determined
by P04.28.
1:
AI1 setting voltage
2:
AI2 setting voltage
3:
AI3 setting voltage
4:
HDI setting voltage
5:
Multi-step speed setting voltage
6:
PID setting voltage
7:
MODBUS communication setting voltage
8~10:
Reserved
Note:
100% corresponds to the rated voltage of the motor.
0.0%
○
P04.28
Keypad setting
voltage
The function code is the voltage digital set value when the
voltage setting channel is selected as “keypad selection”
The setting range: 0.0%~100.0%
100.0%
○
P04.29
Voltage
increasing time
Voltage increasing time is the time when the inverter
accelerates from the output minimum voltage to the output
maximum voltage.
Voltage decreasing time is the time when the inverter
decelerates from the output maximum voltage to the output
minimum voltage.
The setting range: 0.0~3600.0s
5.0s
○
P04.30
Voltage
decreasing
time
5.0s
○
P04.31
Output
maximum
voltage
Set the upper and low limit of the output voltage.
The setting range of P04.31: P04.32~100.0%
(the rated voltage of the motor)
100.0%
◎