Function Parameters
77 - 140
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P10.20
Multi-step
speed 9
combination code of S1, S2, S3, and S4.
The start-up and stopping of multi-step running is determined
by function code P00.06, the relationship between
S1,S2,S3,S4 terminals and multi-step speed is as follows:
S1 OFF ON
OFF ON OFF ON OFF ON
S2 OFF OFF
ON ON OFF OFF ON ON
S3 OFF OFF OFF OFF ON ON ON ON
S4 OFF OFF OFF OFF OFF OFF OFF OFF
stage 0
1
2
3
4
5
6
7
S1 OFF ON
OFF ON OFF ON OFF ON
S2 OFF OFF
ON ON OFF OFF ON ON
S3 OFF OFF OFF OFF ON ON ON ON
S4
ON ON
ON ON ON ON ON ON
stage 8
9
10
11 12 13 14 15
Setting range of P10.(2n,1<n<17): -100.0~100.0%
Setting range of P10.(2n+1, 1<n<17): 0.0~6553.5s (min)
0.0%
○
P10.21
Running time
of stage 9
0.0s
○
P10.22
Multi-step
speed 10
0.0%
○
P10.23
Running time
of stage 10
0.0s
○
P10.24
Multi-step
speed 11
0.0%
○
P10.25
Running time
of stage 11
0.0s
○
P10.26
Multi-step
speed 12
0.0%
○
P10.27
Running time
of stage 12
0.0s
○
P10.28
Multi-step
speed 13
0.0%
○
P10.29
Running time
of stage 13
0.0s
○
P10.30
Multi-step
speed 14
0.0%
○
P10.31
Running time
of stage 14
0.0s
○
P10.32
Multi-step
speed 15
0.0%
○
P10.33
Running time
of stage 15
0.0s
○
P10.34
Simple PLC
0~7 stage
ACC/DEC time
selection
Below is the detailed instruction:
Function
code
Binary bit Stage
ACC/
DEC 0
ACC/
DEC 1
ACC/
DEC 2
ACC/
DEC 3
P10.34
BIT1
BIT0
0
00
01
10
11
BIT3
BIT2
1
00
01
10
11
BIT5
BIT4
2
00
01
10
11
BIT7
BIT6
3
00
01
10
11
BIT9
BIT8
4
00
01
10
11
0x0000
○
P10.35
Simple PLC
8~15 stage
ACC/DEC time
selection
0x0000
○