Installation Guidelines
19 - 140
Type
Terminal name
Function
description
Technical specifications
S4
4. Max. input frequency: 1kHz
HDI
High frequency
input channel
Except for S1~S4, this terminal can be
used as high frequency input channel.
Max. input frequency: 50kHz
Duty cycle: 30%~70%
PW
Digital power supply
To provide the external digital power
supply. Voltage range: 12~30V
Y1
Digital output
Contact capacity: 50mA/30V
24V power
supply
+24V
24V power supply
External 24V
±
10% power supply and
the maximum output current is 200mA.
Generally used as the operation power
supply of digital input and output or
external sensor power supply
COM
Analog
input/output
+10V
External 10V
reference power
supply
10V reference power supply
Max. output current: 50mA
Used as the adjusting power supply of
the external potentiometer
Potentiometer resistance: 5k
Ω
above
AI2
Analog input
1. Input range: AI2 voltage and current can be
chose: 0~10V/0~20mA; AI3:-10V~+10V.
2. Input impedance: for voltage input,
20k
Ω
; for current input, 500
Ω
.
3.Voltage or current input can be
set by dip switch
4. Resolution: the minimum AI2/AI3 is
10mV/20mV when 10V corresponds to 50Hz.
AI3
GND
Analog reference
ground
Analog reference ground
AO1
Analog output
1. Output range: 0~10V or 0~20mA
2. The voltage or the current output
selection depends on the dip switch
3. Deviation ±1%, 25°C when full range
AO2
Relay output
RO1A
Relay 1 NO contact
RO1 relay output, RO1A NO, RO1B NC,
RO1C common terminal
RO2 relay output, RO2A NO, RO2B NC,
RO2C common terminal
Contact capacity: 3A/AC250V
RO1B
Relay 1 NC contact
RO1C
Relay 1 common
contact
RO2A
Relay 2 NO contact
RO2B
Relay 2 NC contact
RO2C
Relay 2 common cont.