70 - 140
Fault Tracking
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
2:
Only analog potentiometer adjustments are valid
3:
Neither
∧
/
∨
keys nor analog potentiometer adjustments
are valid
LED tens
: frequency control selection
0:
Only valid when P00.06=0 or P00.07=0
1
: Valid for all frequency setting manner
2:
Invalid for multi-step speed when multi-step speed has the
priority
LED hundreds:
action selection during stopping
0:
Setting is valid
1:
Valid during running, cleared after stopping
2:
Valid during running, cleared after receiving the stop
command
LED thousands:
∧
/
∨
keys and analog potentiometer
integral function
0:
The Integral function is valid
1:
The Integral function is invalid
P08.43
Integral ratio of
the keypad
potentiometer
0.01~10.00s
0.10s
○
P08.44
UP/DOWN
terminals
control setting
0x00~0x221
LED ones
: frequency control selection
0:
UP/DOWN terminals setting valid
1:
UP/DOWN terminals setting invalid
LED tens:
frequency control selection
0:
Only valid when P00.06=0 or P00.07=0
1:
All frequency means are valid
2:
When the multi-step are priority, it is invalid to the
multi-step
LED hundreds
: action selection when stop
0:
Setting valid
1:
Valid in the running, clear after stop
2:
Valid in the running, clear after receiving the stop
commands
0x000
○
P08.45
UP terminal
frequency
changing ratio
0.01~50.00 Hz/s
0.50
Hz/s
○
P08.46
DOWN
terminal
frequency
0.01~50.00 Hz/s
0.50
Hz/s
○