114 - 140
Communication protocol
Function
instruction
Address
definition
Data meaning instruction
R/W
characteristics
2004H
Torque setting value (-3000~3000), 1000
corresponds to the 100.0% of the rated current
of the motor
W/R
2005H
The upper limit frequency setting during forward
rotation (0~Fmax) Unit: 0.01Hz
W/R
2006H
The upper limit frequency setting during reverse
rotation (0~Fmax) Unit: 0.01Hz
W/R
2007H
The upper limit torque of electromotion torque
(0~3000) 1000 corresponds to the 100.0% of the
rated current of the motor
W/R
2008H
The upper limit torque of braking torque
(0~3000) 1000 corresponds to the 100.0% of the
rated current of the motor
W/R
2009H
Special control command word
Bit0~1:=00:motor
Bit2:=1 torque control prohibit
=0: torque control prohibit invalid
Bit3: =1 power consumption clear
=0: no power consumption clear
Bit4: =1 pre-exciting =0: pre-exciting
prohibition
Bit5: =1 DC braking =0: DC braking prohibition
W/R
200AH
Virtual input terminal command , range:
0x000~0x1FF
W/R
200BH
Virtual input terminal command , range:
0x00~0x0F
W/R
200CH
Voltage setting value (special for V/F separation)
(0~1000, 1000 corresponds to the 100.0% of the
rated voltage of the motor)
W/R
200DH
AO output setting 1
(-1000~1000, 1000 corresponds to 100.0%)
W/R
200EH
AO output setting 2
(-1000~1000, 1000 corresponds to 100.0%)
W/R
SW 1 of the inverter
2100H
0001H: forward running
R
0002H: reverse running
0003H: stop
0004H: fault
0005H: Power Off state
0006H: pre-exciting state