087
0: AC asynchronous motor
1: PMSM (permanent magnet synchronous
motor) (reserved)
Asynchronous motor only accepts closed
loop vector control at present.
F2 Auxiliary Run Parameter
F2.00
motor type
0 ~ 1
0
F2.01
Motor's rated power
0.4 ~ 999.9KW
Depending
on model
F2.02
Motor's rated frequency
0.01Hz ~【F0.15】
max. output freq.
50.00
F2.03
Motor's rated speed
0 ~ 60000RPM
Depending
on model
F2.04
Motor's rated voltage
0 ~ 999V
Depending
on model
F2.05
Motor's rated current
0.1 ~ 6553.5A
Depending
on model
These above motor parameters have specific
implications as showed in figure F2-1.
F2.06
Stator resistance of asynchronous motor
0.001 ~ 20.000Ω
Depending
on model
F2.07
Rotor resistance of asynchronous motor
0.001 ~ 20.000Ω
Depending
on model
F2.08
Stator/rotor inductance of
asynchronous motor
0.1 ~ 6553.5mH
Depending
on model
F2.09
Stator/rotor mutual inductance of
asynchronous motor
0.1 ~ 6553.5mH
Depending
on model
F2.10
No-Ioad current of asynchronous motor
0.01 ~ 655.35A
Depending
on model
Notice
These above function codes must be set
according to motor nameplate parameter.
And please deploy the corresponding
motor according the the VFD power, or the
control performance of VFD will decrease if
the motor power differs too much from VFD
power.
0: over zero frequency switch
1: over start frequency switch
F1.35
FWD/REV switch mode
0 ~ 1
0
For details check NO.10 item function
description of discrete input terminal
(F7.00 ~ F7.07).
F1.36
emergency stop standby
deceleration time
0.1 ~ 3600.0S
1.0
Fig. F2-1 Steady State Equivalent
Circuit of Asynchronous Motor
K9
*
3
9N
*P
6
4 3
4
*
3
K9
4.2 Detailed Function Description
Содержание SKI600
Страница 3: ......
Страница 4: ...88888 Operating Instruction Manual High performance Vector Inverter ...
Страница 179: ......
Страница 180: ......