037
4.1 Function Code
F2 Group - Motor Parameters
Function
Code
Name
Set Range
Minimum
Unit
Factory
Default
Modification
F2.10
No-load current
of asynchronous
motor
0.01 ~ 655.35A
0.01A Depending
on model
×
F2.11-
F2.15
Reserved
—
—
0
◆
F2.16
Motor tuning
0: no action
1: static tuning
2: no-load complete tuning
3: on-load complete tuning
1
0
×
F2.17
pre-excitation time
of asynchronous
motor
0.00 ~ 10.00s
0.4 ~ 4.0KW 0.05s
5.5 ~ 30KW 0.1s
37 ~ 132KW 0.30s
160 ~ 630KW 0.50s
note: invalid for VF control
0.01s Depending
on model
×
F3 Group - Reserved Parameters
F4 Group - Speed Loop, Torque and Flux Control Parameters
F4.00
Speed loop (ASR1)
proportional gain
0.000 ~ 6.000
0.001
1.000
○
F4.01
Speed loop (ASR1)
integral time
0.000 ~ 32.000s
0.001s
1.000
○
F4.02
ASR1 filter time
constant
0.000 ~ 0.100s
0.001s
0.000
○
F4.03
Switch low point
freq.
0.00Hz ~【F4.07】
0.01Hz
5.00
○